Resistive wall impedance calculations and effects of NEG coated insertion device vacuum pipes for the PF-HLS ring

I show analytical expressions of the longitudinal and transverse impedances of a two-layered circular pipe and their practical expressions at high frequencies derived by using asymptotic expansions of the Bessel functions. These expressions are applied to resistive-wall impedance calculations of NEG-coated insertion-device(ID) pipes for the PF-HLS ring*, which is proposed as a 2.5/5.0 GeV energy switchable ring and can simultaneously provide synchrotron light pulses emitted by electron bunches stored in the ring and by extremely short electron bunches (50 fs in length) injected from the superconducting linac. Both real and imaginary parts of the impedances rise up in high frequency regions depending on the NEG coating thickness. The heating powers of the ID pipes are calculated from the real parts of the longitudinal impedances for the stored electron beam and for the short electron bunches injected from the superconducting linac. The kick factors and the coherent betatron tune shifts due to the ID pipes are calculated from the imaginary parts of the transverse impedances for the stored electron beam. These dependences on the NEG-coating thickness are shown in this presentation.

Publication Details

Journal
JACOW
Published
2025-11-05
DOI
https://doi.org/10.18429/jacow-ipac2025-wepm077
Primary Topic
Particle Accelerators and Free-Electron Lasers
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Resistive wall impedance calculations and effects of NEG coated insertion device vacuum pipes for the PF-HLS ring

JACOW
Particle Accelerators and Free-Electron Lasers
article

Resistive wall impedance calculations and effects of NEG coated insertion device vacuum pipes for the PF-HLS ring

article en

Abstract

I show analytical expressions of the longitudinal and transverse impedances of a two-layered circular pipe and their practical expressions at high frequencies derived by using asymptotic expansions of the Bessel functions. These expressions are applied to resistive-wall impedance calculations of NEG-coated insertion-device(ID) pipes for the PF-HLS ring*, which is proposed as a 2.5/5.0 GeV energy switchable ring and can simultaneously provide synchrotron light pulses emitted by electron bunches stored in the ring and by extremely short electron bunches (50 fs in length) injected from the superconducting linac. Both real and imaginary parts of the impedances rise up in high frequency regions depending on the NEG coating thickness. The heating powers of the ID pipes are calculated from the real parts of the longitudinal impedances for the stored electron beam and for the short electron bunches injected from the superconducting linac. The kick factors and the coherent betatron tune shifts due to the ID pipes are calculated from the imaginary parts of the transverse impedances for the stored electron beam. These dependences on the NEG-coating thickness are shown in this presentation.

JACOW
Affordable and clean energy
Openalex Percentile: Top 48%
Particle Accelerators and Free-Electron Lasers
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Resistive wall impedance calculations and effects of NEG coated insertion device vacuum pipes for the PF-HLS ring · JACOW (2025) | TGRS Research Map | TGRS