Simulation studies on optimization of hard and soft X-ray beamlines for parallel user service at the PAL-XFEL

PAL-XFEL (Pohang Accelerator Laboratory X-ray Free Electron Laser) is a facility that generates high-brightness FEL for users to perform the FEL-based sciences. Currently hard and soft X-ray (HX/SX) beamlines are operational, but the parallel operation can be done with less than 60 Hz using a single electron bunch from the electron injector. Therefore, for the user service with maximum repetition rate of 60 Hz on both HX and SX beamlines, a scheme that uses two bunches from the injector with an exact single cycle of 2.856 GHz frequency is under consideration. Particularly, simulation study is necessary to understand the optimal accelerator condition for both HX and SX since the SX shares the same accelerator condition up to the third accelerating column with the HX beamline. In this study, we show discussions using the particle tracking simulations showing the optimal conditions for both beamlines. We also present the potential issues to be considered in the actual operations such as error of RF cavity amplitude.

Publication Details

Journal
JACOW
Published
2025-11-05
DOI
https://doi.org/10.18429/jacow-ipac2025-mopb098
Primary Topic
Particle Accelerators and Free-Electron Lasers
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Simulation studies on optimization of hard and soft X-ray beamlines for parallel user service at the PAL-XFEL

JACOW
Particle Accelerators and Free-Electron Lasers
article

Simulation studies on optimization of hard and soft X-ray beamlines for parallel user service at the PAL-XFEL

article en

Abstract

PAL-XFEL (Pohang Accelerator Laboratory X-ray Free Electron Laser) is a facility that generates high-brightness FEL for users to perform the FEL-based sciences. Currently hard and soft X-ray (HX/SX) beamlines are operational, but the parallel operation can be done with less than 60 Hz using a single electron bunch from the electron injector. Therefore, for the user service with maximum repetition rate of 60 Hz on both HX and SX beamlines, a scheme that uses two bunches from the injector with an exact single cycle of 2.856 GHz frequency is under consideration. Particularly, simulation study is necessary to understand the optimal accelerator condition for both HX and SX since the SX shares the same accelerator condition up to the third accelerating column with the HX beamline. In this study, we show discussions using the particle tracking simulations showing the optimal conditions for both beamlines. We also present the potential issues to be considered in the actual operations such as error of RF cavity amplitude.

JACOW
Openalex Percentile: Top 48%
Particle Accelerators and Free-Electron Lasers
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Simulation studies on optimization of hard and soft X-ray beamlines for parallel user service at the PAL-XFEL · JACOW (2025) | TGRS Research Map | TGRS