Field measurements of a short period helical superconducting undulator

Superconducting undulators (SCUs) may be capable of generating stronger magnetic fields at shorter periods than can be achieved using permanent magnet undulators. Therefore, the range of x-ray wavelengths that an XFEL facility can generate for users could be expanded by exploiting SCU technology. Prototyping work is ongoing at STFC to build a helical superconducting undulator (HSCU) with 13 mm period and 5 mm magnetic gap designed for future XFEL facilities. As part of this work, a test cryostat has been built to cool 325 mm long prototype magnets to 4 K and to measure the field profile of the HSCU using a cryogenic Hall sensor. The magnetic field measurements are necessary to confirm the peak-to-peak field quality and trajectory wander of an electron beam through the device. These quantities must be measured to understand the impact of the HSCU on the FEL radiation output. The trajectory wander can be minimised through the use of field integral corrector coils at either end of the HSCU coil. We present here a description of the test cryostat and the results of the magnetic field measurement regime performed on the prototype HSCU coil.

Publication Details

Journal
JACOW
Published
2025-11-05
DOI
https://doi.org/10.18429/jacow-ipac2025-wepb057
Primary Topic
Particle Accelerators and Free-Electron Lasers
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Field measurements of a short period helical superconducting undulator

JACOW
Particle Accelerators and Free-Electron Lasers
article

Field measurements of a short period helical superconducting undulator

article en

Abstract

Superconducting undulators (SCUs) may be capable of generating stronger magnetic fields at shorter periods than can be achieved using permanent magnet undulators. Therefore, the range of x-ray wavelengths that an XFEL facility can generate for users could be expanded by exploiting SCU technology. Prototyping work is ongoing at STFC to build a helical superconducting undulator (HSCU) with 13 mm period and 5 mm magnetic gap designed for future XFEL facilities. As part of this work, a test cryostat has been built to cool 325 mm long prototype magnets to 4 K and to measure the field profile of the HSCU using a cryogenic Hall sensor. The magnetic field measurements are necessary to confirm the peak-to-peak field quality and trajectory wander of an electron beam through the device. These quantities must be measured to understand the impact of the HSCU on the FEL radiation output. The trajectory wander can be minimised through the use of field integral corrector coils at either end of the HSCU coil. We present here a description of the test cryostat and the results of the magnetic field measurement regime performed on the prototype HSCU coil.

JACOW
Openalex Percentile: Top 48%
Particle Accelerators and Free-Electron Lasers
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Field measurements of a short period helical superconducting undulator · JACOW (2025) | TGRS Research Map | TGRS