Numerical and Experimental Analysis of Heat Transfer Rate and Effectiveness of Gas-solid Cyclone Heat Exchanger

In this article heat transfer rate and effectiveness analysis were carried out on tangential inlet gas solid cyclone heat exchanger, numerically and experimentally varying with input parameters such as velocity of air (5 - 25 m/s), solid mass feeding (0.5 - 2.5 g/s) and particle size (300 - 500 µm) at a constant input air temperature of 473 K. Computational Fluid Dynamics (CFD) software, Ansys Fluent R21 were used to analyze swirl flow in cyclone heat exchanger using RSM turbulence model and particles were analyzed using Discrete Phase model (DPM). Results revealed that increasing the air velocity enhances the heat transmission from 42 W to 82 W and improves effectiveness from 0.64 to 0.88, attributed to increased turbulence and extended residence time for better heat exchange. Increasing solid feed rate raised heat transfer from 42 W to 196 W due to increased quantity of particles available for heat exchange; however, effectiveness slightly decreased from 0.64 to 0.56 due to reduced exit temperature and residence time. Larger particles led to decreased heat transfer rate (289 W to 251 W) and effectiveness (0.55 to 0.45), as they took a lesser number of turns inside the heat exchanger before exiting the cyclone, limiting heat transmission. The CFD simulation confirmed the cyclone heat exchanger design reliability and efficiency by demonstrating strong agreement with experimental data and aligned with literature, with a variance in heat transfer rate ranging from 10% to 19%, confirming the reliability and efficiency of the cyclone heat exchanger design. The effectiveness value of CFD is also well aligned with experimental results, with an R2 value of 0.976.

Institutions

Publication Details

Journal
Journal of Applied Fluid Mechanics
Published
2025-11-07
DOI
https://doi.org/10.47176/jafm.19.1.3688
Citations
1
Primary Topic
Cyclone Separators and Fluid Dynamics
Type
article
Field-Weighted Citation Impact
1.33

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Numerical and Experimental Analysis of Heat Transfer Rate and Effectiveness of Gas-solid Cyclone Heat Exchanger

1 citations
Journal of Applied Fluid Mechanics
Cyclone Separators and Fluid Dynamics
1.33
article

Numerical and Experimental Analysis of Heat Transfer Rate and Effectiveness of Gas-solid Cyclone Heat Exchanger

article en
1 citations

Abstract

In this article heat transfer rate and effectiveness analysis were carried out on tangential inlet gas solid cyclone heat exchanger, numerically and experimentally varying with input parameters such as velocity of air (5 - 25 m/s), solid mass feeding (0.5 - 2.5 g/s) and particle size (300 - 500 µm) at a constant input air temperature of 473 K. Computational Fluid Dynamics (CFD) software, Ansys Fluent R21 were used to analyze swirl flow in cyclone heat exchanger using RSM turbulence model and particles were analyzed using Discrete Phase model (DPM). Results revealed that increasing the air velocity enhances the heat transmission from 42 W to 82 W and improves effectiveness from 0.64 to 0.88, attributed to increased turbulence and extended residence time for better heat exchange. Increasing solid feed rate raised heat transfer from 42 W to 196 W due to increased quantity of particles available for heat exchange; however, effectiveness slightly decreased from 0.64 to 0.56 due to reduced exit temperature and residence time. Larger particles led to decreased heat transfer rate (289 W to 251 W) and effectiveness (0.55 to 0.45), as they took a lesser number of turns inside the heat exchanger before exiting the cyclone, limiting heat transmission. The CFD simulation confirmed the cyclone heat exchanger design reliability and efficiency by demonstrating strong agreement with experimental data and aligned with literature, with a variance in heat transfer rate ranging from 10% to 19%, confirming the reliability and efficiency of the cyclone heat exchanger design. The effectiveness value of CFD is also well aligned with experimental results, with an R2 value of 0.976.

Journal of Applied Fluid MechanicsVol. 19(1)
SRM Institute of Science and Technology (IN), Dr. M.G.R. Educational and Research Institute (IN), Tamil Nadu Dr. J Jayalalitha Fisheries University (IN), SRM Dental College (IN)
SRM Institute of Science and Technology
Affordable and clean energy
Openalex Percentile: Top 16%
Cyclone Separators and Fluid Dynamics
1.33
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Numerical and Experimental Analysis of Heat Transfer Rate and Effectiveness of Gas-solid Cyclone Heat Exchanger · Journal of Applied Fluid Mechanics (2025) | TGRS Research Map | TGRS