RHIC polarized proton operation in Run24

The Relativistic Heavy Ion Collider (RHIC) Run 24 was 27 cryo weeks, operating with collisions at the STAR and sPHENIX detectors. The primary mode was polarized protons at 100 GeV, where there was 22 weeks of physics production. sPHENIX continued commissioning, becoming fully operational after 13 weeks and the addition of isobutane to their TPC gas mixture. STAR had a low luminosity run followed by twenty weeks of high luminosity and radially polarized beams. To reduce the beam-beam parameter and maximize the number of collisions within a small vertex region at sPHENIX, sPHENIX planned to operate with a crossing angle. For 8 weeks, collisions were only at sPHENIX until the beam-beam parameter was sufficiently low to support the additional collisions at STAR. A significant number of power dips earlier in the run greatly affected machine performance and reliability. At the maximum achieved performance, the luminosity was limited by four factors simultaneously: accelerating RF cavity intensity limit, intensity from the injectors, losses at rebucketing, and dynamic aperture. Despite these difficulties, sPHENIX and STAR were able to collect sufficient data commensurate with their goals.

Publication Details

Journal
JACOW
Published
2025-11-05
DOI
https://doi.org/10.18429/jacow-ipac2025-tubn2
Primary Topic
Particle Accelerators and Free-Electron Lasers
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

RHIC polarized proton operation in Run24

JACOW
Particle Accelerators and Free-Electron Lasers
article

RHIC polarized proton operation in Run24

article en

Abstract

The Relativistic Heavy Ion Collider (RHIC) Run 24 was 27 cryo weeks, operating with collisions at the STAR and sPHENIX detectors. The primary mode was polarized protons at 100 GeV, where there was 22 weeks of physics production. sPHENIX continued commissioning, becoming fully operational after 13 weeks and the addition of isobutane to their TPC gas mixture. STAR had a low luminosity run followed by twenty weeks of high luminosity and radially polarized beams. To reduce the beam-beam parameter and maximize the number of collisions within a small vertex region at sPHENIX, sPHENIX planned to operate with a crossing angle. For 8 weeks, collisions were only at sPHENIX until the beam-beam parameter was sufficiently low to support the additional collisions at STAR. A significant number of power dips earlier in the run greatly affected machine performance and reliability. At the maximum achieved performance, the luminosity was limited by four factors simultaneously: accelerating RF cavity intensity limit, intensity from the injectors, losses at rebucketing, and dynamic aperture. Despite these difficulties, sPHENIX and STAR were able to collect sufficient data commensurate with their goals.

JACOW
Affordable and clean energy
Openalex Percentile: Top 48%
Particle Accelerators and Free-Electron Lasers
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.