Optical and laser systems for the AWAKE run 2C experiment
In the AWAKE Run 2c experiment, two electron beams are injected into two separate rubidium (Rb) vapour sources. The first electron beam initiates the self-modulation of a proton bunch in the first vapour source, while the second electron beam serves as a witness beam for plasma wakefield acceleration with low energy spread in the second vapour source. This setup requires the precise spatio-temporal delivery of four laser beams: two deep UV beams that generate the electron beams with a relative timing jitter well below 100 fs, and two near-IR beams that ionize efficiently the Rb vapour sources. The UV pulses are generated by an established Yb laser system, capable of producing 400 uJ, 0.2-10 ps pulses at 257 nm with high reliability (<0.1% RMS energy fluctuation), and enables emittance optimization via spatial beam shaping. The same system is used for both electron sources, utilizing a partial reflector to split the beam and account for differing photocathode yields. For the Rb ionizing pulses, which are directed into the vapour sources in a counter-propagating geometry, the pulses from the AWAKE Ti:Sapphire laser system are transported using a series of vacuum relay telescopes.
Publication Details
- Journal
- International Linear Collider
- Published
- 2025-11-05
- DOI
- https://doi.org/10.18429/jacow-ipac2025-tups111
- Primary Topic
- Particle Accelerators and Free-Electron Lasers
- Type
- article
- Field-Weighted Citation Impact
- 0.00