Passive Radiation Detection Using TLD in NSRRC

The NSRRC is a research facility and currently op-erates two synchrotron accelerators: the Taiwan Light Source (TLS), featuring a beam energy of 1.5 GeV and a circumference of 120 meters, and the Taiwan Photon Source (TPS), with a beam energy of 3 GeV and a cir-cumference of 518.4 meters. There are hundreds of users in 40 beamlines among TPS and TLS experi-mental floors. The Thermo-Luminescent Dosimeter (TLD) is a compact instrument utilizing well-established detec-tion technology. To ensure radiation intensity at NSRRC workplace as close to background radiation levels as possible, we have deployed approximately 200 TLDs among these two accelerators. For each BL, three points are selected: the optical hutch near accel-erator shielding wall, the user experimental area with the highest occupancy, and the BL rear end. Additional TLDs are strategically placed around the accelerator's surroundings, including both the outer and inner sur-face of the shielding tunnel, downstream of the injec-tion section, the roof and downstream area of the RF cavities. In this paper, we will present the detection data col-lected at NSRRC over the past several years to reflect the proficiency of our radiation protection program.

Publication Details

Journal
JACOW
Published
2025-11-05
DOI
https://doi.org/10.18429/jacow-ipac2025-thps025
Primary Topic
Radiation Therapy and Dosimetry
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Passive Radiation Detection Using TLD in NSRRC

JACOW
Radiation Therapy and Dosimetry
article

Passive Radiation Detection Using TLD in NSRRC

article en

Abstract

The NSRRC is a research facility and currently op-erates two synchrotron accelerators: the Taiwan Light Source (TLS), featuring a beam energy of 1.5 GeV and a circumference of 120 meters, and the Taiwan Photon Source (TPS), with a beam energy of 3 GeV and a cir-cumference of 518.4 meters. There are hundreds of users in 40 beamlines among TPS and TLS experi-mental floors. The Thermo-Luminescent Dosimeter (TLD) is a compact instrument utilizing well-established detec-tion technology. To ensure radiation intensity at NSRRC workplace as close to background radiation levels as possible, we have deployed approximately 200 TLDs among these two accelerators. For each BL, three points are selected: the optical hutch near accel-erator shielding wall, the user experimental area with the highest occupancy, and the BL rear end. Additional TLDs are strategically placed around the accelerator's surroundings, including both the outer and inner sur-face of the shielding tunnel, downstream of the injec-tion section, the roof and downstream area of the RF cavities. In this paper, we will present the detection data col-lected at NSRRC over the past several years to reflect the proficiency of our radiation protection program.

JACOW
Affordable and clean energy
Openalex Percentile: Top 33%
Radiation Therapy and Dosimetry
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.