3Qy resonance correction at LHC injection
Compensation of the 3Qy resonance at injection energy in the LHC is of significant interest, given its potential to degrade the lifetime of high-intensity beams. In the absence of dedicated corrector circuits for the 3Qy compensation of each beam at low energy, an alternative approach is needed. Using skew-sextupoles in the four common experimental insertions it has been possible to develop a scheme to independently control the 3Qy resonance of the two LHC beams. Beam-based measurements and corrections of the 3Qy resonance at injection were performed, with beneficial impacts on lifetime and emittance growth observed.
Publication Details
- Journal
- CERN Bulletin
- Published
- 2025-11-05
- DOI
- https://doi.org/10.18429/jacow-ipac2025-wepm008
- Primary Topic
- Particle Accelerators and Free-Electron Lasers
- Type
- article
- Field-Weighted Citation Impact
- 0.00