Return of experience in the commissioning of the new CLS LINAC injector

After more than 40 years of services the 2856~MHz linac injector of The Canadian Light Source (CLS) has been retired to leave space for a new 3000.24~MHz linac injector, the frequency of which is a multiple of the 500.04~MHz CESR-B type superconductive radio frequency cavity. The new CLS linac injector has been designed and built by RI Research Instruments GmbH. The design is based on their robust S-band technology RF structures that already serve other laboratories in the USA, Australia, Taiwan, Switzerland and Sweden. In order to save money and space the CLS has replaced its six long Accelerating RF structures (3.4~m long) delivering 250~MeV electron beam by three 5~m long accelerating structures that will deliver the same beam energy. In order to do so, one RF structure is powered by one modulator-klystron and the last two RF structures received their RF power from a second modulator-klystron that passes through a SLED system. The SLED system multiplies the power by a factor 5 to 6 and is then equally split to power each structure. We are reporting on the progress of the commissioning of this new injector.

Publication Details

Journal
JACOW
Published
2025-11-05
DOI
https://doi.org/10.18429/jacow-ipac2025-tupm003
Primary Topic
Particle Accelerators and Free-Electron Lasers
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Return of experience in the commissioning of the new CLS LINAC injector

JACOW
Particle Accelerators and Free-Electron Lasers
article

Return of experience in the commissioning of the new CLS LINAC injector

article en

Abstract

After more than 40 years of services the 2856~MHz linac injector of The Canadian Light Source (CLS) has been retired to leave space for a new 3000.24~MHz linac injector, the frequency of which is a multiple of the 500.04~MHz CESR-B type superconductive radio frequency cavity. The new CLS linac injector has been designed and built by RI Research Instruments GmbH. The design is based on their robust S-band technology RF structures that already serve other laboratories in the USA, Australia, Taiwan, Switzerland and Sweden. In order to save money and space the CLS has replaced its six long Accelerating RF structures (3.4~m long) delivering 250~MeV electron beam by three 5~m long accelerating structures that will deliver the same beam energy. In order to do so, one RF structure is powered by one modulator-klystron and the last two RF structures received their RF power from a second modulator-klystron that passes through a SLED system. The SLED system multiplies the power by a factor 5 to 6 and is then equally split to power each structure. We are reporting on the progress of the commissioning of this new injector.

JACOW
Affordable and clean energy
Openalex Percentile: Top 48%
Particle Accelerators and Free-Electron Lasers
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.