Development of the beam separation test device to evaluate the electric field of non-destructive electrostatic septum

Slow beam the extraction in synchrotrons is utilized for various nuclear and particle physics experiments and radiology. A beam loss at a septum electrode induces equipment activation and damage. We have been developing a non-destructive electrostatic septum. This septum has multiple electrodes, and those are placed around the outside of the beam. Measuring the 2-D electric field distribution of this septum is important to evaluate the beam loss reduction due to this septum. We are developing the beam separation test device consists of a prototype septum, horizontal and vertical wire scanners and the electron gun installed on a movable stage fixed to a drive unit. This device measures the electric field by injecting an electron beam into the electric field and measuring the bending angle of the beam orbit. Since the width of the electron beam determines the resolution of the measurement data, we developed an additional lens system that can transport the beam 1.5 m with a width of 1 mm. We used a square chamber for the 2-D measurement system. A permalloy magnetic shield is installed inside the chamber and reduces the external magnetic field from 50 $\mu$T to less than 1.5 $\mu$T.

Publication Details

Journal
JACOW
Published
2025-11-05
DOI
https://doi.org/10.18429/jacow-ipac2025-tupb028
Primary Topic
Particle Accelerators and Free-Electron Lasers
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of the beam separation test device to evaluate the electric field of non-destructive electrostatic septum

JACOW
Particle Accelerators and Free-Electron Lasers
article

Development of the beam separation test device to evaluate the electric field of non-destructive electrostatic septum

article en

Abstract

Slow beam the extraction in synchrotrons is utilized for various nuclear and particle physics experiments and radiology. A beam loss at a septum electrode induces equipment activation and damage. We have been developing a non-destructive electrostatic septum. This septum has multiple electrodes, and those are placed around the outside of the beam. Measuring the 2-D electric field distribution of this septum is important to evaluate the beam loss reduction due to this septum. We are developing the beam separation test device consists of a prototype septum, horizontal and vertical wire scanners and the electron gun installed on a movable stage fixed to a drive unit. This device measures the electric field by injecting an electron beam into the electric field and measuring the bending angle of the beam orbit. Since the width of the electron beam determines the resolution of the measurement data, we developed an additional lens system that can transport the beam 1.5 m with a width of 1 mm. We used a square chamber for the 2-D measurement system. A permalloy magnetic shield is installed inside the chamber and reduces the external magnetic field from 50 $\mu$T to less than 1.5 $\mu$T.

JACOW
Affordable and clean energy
Openalex Percentile: Top 48%
Particle Accelerators and Free-Electron Lasers
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.