Cryogenic inserts in the room temperature synchrotron SIS18 at GSI

The existing room temperature heavy ion synchrotron SIS18 at GSI will be used as booster for the future SIS100 at FAIR. One of its features the the generation of high intensity heavy ion beams. In order to create such beams, medium charge states are used, which have a lower space charge limit and can be created with less stripping losses. Unfortunately, such heavy ions have very high ionization cross sections in collisions with residual gas particles, yielding in beam loss and subsequent pressure rises via ion impact stimulated gas desorption. Although an extensive upgrade plan, including NEG-coated magnet chambers and an ion-catcher system, has been realized, the required intesity goals will not yet be reached. Simulations including cryogenic surfaces around the ion catchers show, that their high sticking probability prevents from pressure built-ups during operation. A prototype ion catcher, including such cryogenic surfaces cooled by a commercial cold-head has been developed, built, and tested. It has recently been installed in SIS18 and will undergo further tests, including measurements with heavy ion beams. Findings for the operation and further cryogenic inserts are presented.

Publication Details

Journal
JACOW
Published
2025-11-05
DOI
https://doi.org/10.18429/jacow-ipac2025-thps058
Primary Topic
Superconducting Materials and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Cryogenic inserts in the room temperature synchrotron SIS18 at GSI

JACOW
Superconducting Materials and Applications
article

Cryogenic inserts in the room temperature synchrotron SIS18 at GSI

article en

Abstract

The existing room temperature heavy ion synchrotron SIS18 at GSI will be used as booster for the future SIS100 at FAIR. One of its features the the generation of high intensity heavy ion beams. In order to create such beams, medium charge states are used, which have a lower space charge limit and can be created with less stripping losses. Unfortunately, such heavy ions have very high ionization cross sections in collisions with residual gas particles, yielding in beam loss and subsequent pressure rises via ion impact stimulated gas desorption. Although an extensive upgrade plan, including NEG-coated magnet chambers and an ion-catcher system, has been realized, the required intesity goals will not yet be reached. Simulations including cryogenic surfaces around the ion catchers show, that their high sticking probability prevents from pressure built-ups during operation. A prototype ion catcher, including such cryogenic surfaces cooled by a commercial cold-head has been developed, built, and tested. It has recently been installed in SIS18 and will undergo further tests, including measurements with heavy ion beams. Findings for the operation and further cryogenic inserts are presented.

JACOW
Openalex Percentile: Top 50%
Superconducting Materials and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.