Minimizing disturbance in ion beam profiling with PEPITES monitor

In the field of beam diagnostics for radiotherapy, accurate dose delivery relies on ultra-thin, linear and radioresistant monitors to minimize beam scattering and achieve precise profiling. The first PEPITES prototype monitor features two segmented cathodes, each paired with a high-voltage-biased anode. This latter effectively captures secondary electrons generated by the cathodes when they interact with the beam, enabling the detection of a measurable signal. The Water Equivalent Thickness (WET) of this design is approximately 10 μm*. To achieve efficient profiling of the charged particle beam when the monitor is positioned several meters upstream of the patient, we developed a thinner design. This configuration features two anodes positioned outside the beam path, reducing by half the amount of material that interacts with the beam, thereby minimizing beam disturbances. Both, the previous and the updated PEPITES monitor designs were recently tested at CNAO,Italy. Measurements were successfully conducted using a 115 MeV carbon ion beam at varying high-voltage power. These results will be presented and compared to demonstrate the enhanced efficiency of the upgraded PEPITES version.

Publication Details

Journal
SPIRE - Sciences Po Institutional REpository
Published
2025-11-05
DOI
https://doi.org/10.18429/jacow-ipac2025-thps097
Primary Topic
Radiation Therapy and Dosimetry
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Minimizing disturbance in ion beam profiling with PEPITES monitor

SPIRE - Sciences Po Institutional REpository
Radiation Therapy and Dosimetry
article

Minimizing disturbance in ion beam profiling with PEPITES monitor

article en

Abstract

In the field of beam diagnostics for radiotherapy, accurate dose delivery relies on ultra-thin, linear and radioresistant monitors to minimize beam scattering and achieve precise profiling. The first PEPITES prototype monitor features two segmented cathodes, each paired with a high-voltage-biased anode. This latter effectively captures secondary electrons generated by the cathodes when they interact with the beam, enabling the detection of a measurable signal. The Water Equivalent Thickness (WET) of this design is approximately 10 μm*. To achieve efficient profiling of the charged particle beam when the monitor is positioned several meters upstream of the patient, we developed a thinner design. This configuration features two anodes positioned outside the beam path, reducing by half the amount of material that interacts with the beam, thereby minimizing beam disturbances. Both, the previous and the updated PEPITES monitor designs were recently tested at CNAO,Italy. Measurements were successfully conducted using a 115 MeV carbon ion beam at varying high-voltage power. These results will be presented and compared to demonstrate the enhanced efficiency of the upgraded PEPITES version.

SPIRE - Sciences Po Institutional REpository
Openalex Percentile: Top 33%
Radiation Therapy and Dosimetry
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.