Investigation on injection-related beam loss at SuperKEKB

The current achieved highest luminosity at SuperKEKB is only one-tenth of the design value, and beam injection is one of the most serious issues in achieving the target luminosity. Recent operations in both the HER and LER rings have shown insufficient injection efficiencies and detector backgrounds. The achieved injection efficiency falls short of the required level, sometimes leading to difficulties in injecting the beam at high current values. Following each injection, significant signals from particle losses are detected in several Belle II detector components, particularly the vertex detector, resulting in saturating the data acquisition with a dead time exceeding 10ms. The complexity of the injection, and critical factors like injected beam quality, beam lifetime, dynamic aperture, machine errors, nonlinearity, as well as the collimation system, makes the optimization challenging. Detailed injection simulations are essential to understand the issues of the injection and guide adjustments to maximize the injection efficiency and mitigate the injection background. This paper presents the findings of HER injection simulations and their experimental validation.

Publication Details

Journal
SPIRE - Sciences Po Institutional REpository
Published
2025-11-05
DOI
https://doi.org/10.18429/jacow-ipac2025-mops022
Primary Topic
Particle Accelerators and Free-Electron Lasers
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Investigation on injection-related beam loss at SuperKEKB

SPIRE - Sciences Po Institutional REpository
Particle Accelerators and Free-Electron Lasers
article

Investigation on injection-related beam loss at SuperKEKB

article en

Abstract

The current achieved highest luminosity at SuperKEKB is only one-tenth of the design value, and beam injection is one of the most serious issues in achieving the target luminosity. Recent operations in both the HER and LER rings have shown insufficient injection efficiencies and detector backgrounds. The achieved injection efficiency falls short of the required level, sometimes leading to difficulties in injecting the beam at high current values. Following each injection, significant signals from particle losses are detected in several Belle II detector components, particularly the vertex detector, resulting in saturating the data acquisition with a dead time exceeding 10ms. The complexity of the injection, and critical factors like injected beam quality, beam lifetime, dynamic aperture, machine errors, nonlinearity, as well as the collimation system, makes the optimization challenging. Detailed injection simulations are essential to understand the issues of the injection and guide adjustments to maximize the injection efficiency and mitigate the injection background. This paper presents the findings of HER injection simulations and their experimental validation.

SPIRE - Sciences Po Institutional REpository
Openalex Percentile: Top 48%
Particle Accelerators and Free-Electron Lasers
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Investigation on injection-related beam loss at SuperKEKB · SPIRE - Sciences Po Institutional REpository (2025) | TGRS Research Map | TGRS