FATIGUE CHARACTERISTICS OF 3D-PRINTED CARBON FIBER NYLON 12 (CF/PA12) HIP IMPLANTS

Carbon fiber composite materials are frequently employed in components where cyclic loads could result in fatigue failure. The primary objective of this study was to assess the fatigue behavior of fused modelled, carbon fiber nylon 12 (CF/PA12) hip implants. Structural analysis was carried out using analysis of systems (ANSYS 19 R2) to evaluate the safety of a hip implant design. The hip implant was then printed using a Fusion 3 printing machine, and dog-bone fatigue test specimens were machined and cyclically tested at 50, 60, 70, and 80% of the ultimate tensile stress. Finite element analysis revealed a maximum von Mises stress of 24.401 MPa in the hip implant, which is well below the ultimate strength of 71 MPa for the CF/PA12 implant. This indicated that the CF/PA12 hip implant was resistant to fatigue failure. The cyclic fatigue life results were 5,080,709 cycles at 1043.3 N, 1,146,842 cycles at 1251.9 N, 585,731.50 cycles at 1460.6 N, and 212,237.50 cycles at 1669.2 N. The International Standard Organization requires hip implants to have a minimum fatigue life of 105 cycles under loadings from 300 N to 3000 N. The CF/PA12 composite met this standard for all tested loads, indicating superior fatigue performance.

Institutions

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2025-10-01
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

FATIGUE CHARACTERISTICS OF 3D-PRINTED CARBON FIBER NYLON 12 (CF/PA12) HIP IMPLANTS

SHILAP Revista de lepidopterología
Orthopaedic implants and arthroplasty
article

FATIGUE CHARACTERISTICS OF 3D-PRINTED CARBON FIBER NYLON 12 (CF/PA12) HIP IMPLANTS

article en

Abstract

Carbon fiber composite materials are frequently employed in components where cyclic loads could result in fatigue failure. The primary objective of this study was to assess the fatigue behavior of fused modelled, carbon fiber nylon 12 (CF/PA12) hip implants. Structural analysis was carried out using analysis of systems (ANSYS 19 R2) to evaluate the safety of a hip implant design. The hip implant was then printed using a Fusion 3 printing machine, and dog-bone fatigue test specimens were machined and cyclically tested at 50, 60, 70, and 80% of the ultimate tensile stress. Finite element analysis revealed a maximum von Mises stress of 24.401 MPa in the hip implant, which is well below the ultimate strength of 71 MPa for the CF/PA12 implant. This indicated that the CF/PA12 hip implant was resistant to fatigue failure. The cyclic fatigue life results were 5,080,709 cycles at 1043.3 N, 1,146,842 cycles at 1251.9 N, 585,731.50 cycles at 1460.6 N, and 212,237.50 cycles at 1669.2 N. The International Standard Organization requires hip implants to have a minimum fatigue life of 105 cycles under loadings from 300 N to 3000 N. The CF/PA12 composite met this standard for all tested loads, indicating superior fatigue performance.

SHILAP Revista de lepidopterología
University of Kigali (RW), University of Rwanda (RW), Yibin University (CN)
Openalex Percentile: Top 32%
Orthopaedic implants and arthroplasty
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

FATIGUE CHARACTERISTICS OF 3D-PRINTED CARBON FIBER NYLON 12 (CF/PA12) HIP IMPLANTS · SHILAP Revista de lepidopterología (2025) | TGRS Research Map | TGRS