Identification of vibration and noise sources in EHA internal gear pumps under variable operating conditions and noise reduction design

Hydraulic pump serves as the primary noise source in Electro-Hydraulic Actuator (EHA), with complex variable speed and pressure conditions leading to intricate evolution of EHA pump excitation. This study establishes a fluid–structure-acoustics-coupled prediction model for an EHA internal gear pump, incorporating the effects of mechanical excitations, to accurately identify these vibration and noise excitations under such variable conditions. The model is validated through tests conducted in a semi-anechoic chamber. Results demonstrate a radiated noise prediction error of less than 1.5 dB(A), representing a 28.6 % improvement in accuracy compared to traditional prediction models. The evolution laws and contribution of excitations under variable conditions are also evaluated, and a housing noise reduction design is implemented. The results show that the fluid surface source consistently contributes the most to radiated noise across all operating conditions. Moreover, mechanical excitations contribute significantly at the peak sound pressure frequencies. The fluid volume source is considerably influenced by rotational speed, and under high-speed conditions, pronounced turbulence, cavitation, and trapped oil phenomena make the contribution of the volume source non-negligible. Structural optimization yields a reduction of 3.7 dB(A) in the predicted overall sound pressure level (SPL) of the EHA pump under the rated operating condition, and the average total SPLs under variable pressure and speed working conditions decrease by 1.2 and 2.2 dB(A), respectively. These findings are significant for guiding the noise reduction design of EHA internal gear pumps under variable operating conditions.

Institutions

Publication Details

Journal
Mechanical Systems and Signal Processing
Published
2025-11-06
DOI
https://doi.org/10.1016/j.ymssp.2025.113558
Primary Topic
Hydraulic and Pneumatic Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Identification of vibration and noise sources in EHA internal gear pumps under variable operating conditions and noise reduction design

Mechanical Systems and Signal Processing
Hydraulic and Pneumatic Systems
article

Identification of vibration and noise sources in EHA internal gear pumps under variable operating conditions and noise reduction design

article en

Abstract

Hydraulic pump serves as the primary noise source in Electro-Hydraulic Actuator (EHA), with complex variable speed and pressure conditions leading to intricate evolution of EHA pump excitation. This study establishes a fluid–structure-acoustics-coupled prediction model for an EHA internal gear pump, incorporating the effects of mechanical excitations, to accurately identify these vibration and noise excitations under such variable conditions. The model is validated through tests conducted in a semi-anechoic chamber. Results demonstrate a radiated noise prediction error of less than 1.5 dB(A), representing a 28.6 % improvement in accuracy compared to traditional prediction models. The evolution laws and contribution of excitations under variable conditions are also evaluated, and a housing noise reduction design is implemented. The results show that the fluid surface source consistently contributes the most to radiated noise across all operating conditions. Moreover, mechanical excitations contribute significantly at the peak sound pressure frequencies. The fluid volume source is considerably influenced by rotational speed, and under high-speed conditions, pronounced turbulence, cavitation, and trapped oil phenomena make the contribution of the volume source non-negligible. Structural optimization yields a reduction of 3.7 dB(A) in the predicted overall sound pressure level (SPL) of the EHA pump under the rated operating condition, and the average total SPLs under variable pressure and speed working conditions decrease by 1.2 and 2.2 dB(A), respectively. These findings are significant for guiding the noise reduction design of EHA internal gear pumps under variable operating conditions.

Mechanical Systems and Signal ProcessingVol. 241
Naval University of Engineering (CN), Wuhan Ship Development & Design Institute (CN)
Affordable and clean energy
Openalex Percentile: Top 50%
Hydraulic and Pneumatic Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.