RP-HPLC METHOD DEVELOPMENT AND VALIDATION FOR ESTIMATION OF RELUGOLIX IN BULK AND TABLET DOSAGE FORM

A new simple, precise, accurate, sensitive and rapid chromatographic method based on RP-HPLC was developed and validated for the estimation of Relugolix in bulk and tablet dosage form. Methanol: Water (70:30 v/v)) was used as mobile phase. A isocratic programing has been done, on a reverse phase Qualisil C18, (250 mm× 4.6mm, 5 μm) with rate 0.8 mL/min, monitored at 290 nm. The mean retention times of Relugolix were found to be 4.10 min respectively. Linearity of Relugolix was found to be 2-12 μg/mL, R2= 0.9993 respectively. The developed methods have shown the best findings in terms of linearity, accuracy, precision, LOD and LOQ for API and in tablet. The depicted method can routinely be used for the determination of Relugolix in bulk and tablet formulation.

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2025-11-05
DOI
https://doi.org/10.5281/zenodo.17528857
Primary Topic
Analytical Methods in Pharmaceuticals
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

RP-HPLC METHOD DEVELOPMENT AND VALIDATION FOR ESTIMATION OF RELUGOLIX IN BULK AND TABLET DOSAGE FORM

Zenodo (CERN European Organization for Nuclear Research)
Analytical Methods in Pharmaceuticals
article

RP-HPLC METHOD DEVELOPMENT AND VALIDATION FOR ESTIMATION OF RELUGOLIX IN BULK AND TABLET DOSAGE FORM

article en

Abstract

A new simple, precise, accurate, sensitive and rapid chromatographic method based on RP-HPLC was developed and validated for the estimation of Relugolix in bulk and tablet dosage form. Methanol: Water (70:30 v/v)) was used as mobile phase. A isocratic programing has been done, on a reverse phase Qualisil C18, (250 mm× 4.6mm, 5 μm) with rate 0.8 mL/min, monitored at 290 nm. The mean retention times of Relugolix were found to be 4.10 min respectively. Linearity of Relugolix was found to be 2-12 μg/mL, R2= 0.9993 respectively. The developed methods have shown the best findings in terms of linearity, accuracy, precision, LOD and LOQ for API and in tablet. The depicted method can routinely be used for the determination of Relugolix in bulk and tablet formulation.

Zenodo (CERN European Organization for Nuclear Research)
Shri Vile Parle Kelavani Mandal (IN)
Clean water and sanitation
Openalex Percentile: Top 48%
Analytical Methods in Pharmaceuticals
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.