Robust Estimation of the Effective Sample Size in Mode-Stirred Reverberation Chamber Measurements

A specific measurement methodology should be followed when evaluating effective sample sizes of electric (magnetic) field in a reverberation chamber mode-stirred operation. It is here shown that appropriate coordination between the stirrer movement, the receiver frequency sweep and stirrer repositioning before the start of a series of acquisitions are required, otherwise the effective sample size may be significantly overestimated or underestimated, depending on the specific correlation mechanism under examination. Results reported here for mode stirring are, in part, relevant to vibrating intrinsic reverberation chambers. In particular, our observations strongly suggest that evaluation of electric field correlation and uniformity in a vibrating intrinsic reverberation chamber mandates the use of a simultaneous multiprobe measurement system.

Institutions

Publication Details

Journal
IEEE Transactions on Electromagnetic Compatibility
Published
2025-11-05
DOI
https://doi.org/10.1109/temc.2025.3618326
Primary Topic
Electromagnetic Compatibility and Measurements
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Robust Estimation of the Effective Sample Size in Mode-Stirred Reverberation Chamber Measurements

IEEE Transactions on Electromagnetic Compatibility
Electromagnetic Compatibility and Measurements
article

Robust Estimation of the Effective Sample Size in Mode-Stirred Reverberation Chamber Measurements

article en

Abstract

A specific measurement methodology should be followed when evaluating effective sample sizes of electric (magnetic) field in a reverberation chamber mode-stirred operation. It is here shown that appropriate coordination between the stirrer movement, the receiver frequency sweep and stirrer repositioning before the start of a series of acquisitions are required, otherwise the effective sample size may be significantly overestimated or underestimated, depending on the specific correlation mechanism under examination. Results reported here for mode stirring are, in part, relevant to vibrating intrinsic reverberation chambers. In particular, our observations strongly suggest that evaluation of electric field correlation and uniformity in a vibrating intrinsic reverberation chamber mandates the use of a simultaneous multiprobe measurement system.

IEEE Transactions on Electromagnetic CompatibilityVol. 67(6)
University of Florence (IT), Eindhoven University of Technology (NL)
Openalex Percentile: Top 49%
Electromagnetic Compatibility and Measurements
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.