Intracardiac echocardiography-guided transseptal PFO closure with Swartz SL1 Sheath: A safe and feasible approach for complex cases

Transcatheter closure of patent foramen ovale (PFO) has emerged as an effective therapeutic strategy, demonstrating superiority over medical treatment for patients with cryptogenic stroke (CS) or transient ischemic attack (TIA). This study aimed to evaluate the safety and feasibility of using intracardiac echocardiography (ICE) combined with the Swartz SL1 transseptal sheath for transcatheter PFO closure. This single-center study included consecutive patients with complex PFO, combined CS/TIA, and moderate to high levels of right-to-left shunt (RLS). Initial attempts to traverse the PFO were made using conventional methods; however, for cases where these attempts were unsuccessful, the PFO was subsequently traversed using the Swartz SL1 sheath under ICE and fluoroscopy guidance as a rescue strategy. Eighteen patients were enrolled, and the PFO was traversed using the Swartz SL1 sheath under ICE and fluoroscopy guidance. All procedures were performed under local anesthesia. The time required to traverse the PFO, total procedural duration, fluoroscopy time, and radiation dose were recorded. The mean time to traverse the interatrial septum was 1.62 [1.28–2.03] min, with a fluoroscopy duration of 0.97 [0.72–1.28] s. The total fluoroscopy duration and dose were 4.05 [3.16–6.53] min and 154.7 [57.0–280.0] mGy, respectively. The mean procedural duration was 28.3 ± 6.1 min. The combination of ICE and the Swartz SL1 transseptal sheath is a safe and efficient approach for transcatheter PFO closure, significantly reducing procedural time and radiation exposure compared to conventional methods, thereby enhancing safety. This approach may represent a safer and more efficient alternative to conventional methods, particularly in patients with complex PFO anatomy.

Institutions

Publication Details

Journal
Journal of Radiation Research and Applied Sciences
Published
2025-11-05
DOI
https://doi.org/10.1016/j.jrras.2025.102033
Primary Topic
Cardiovascular and Diving-Related Complications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Intracardiac echocardiography-guided transseptal PFO closure with Swartz SL1 Sheath: A safe and feasible approach for complex cases

Journal of Radiation Research and Applied Sciences
Cardiovascular and Diving-Related Complications
article

Intracardiac echocardiography-guided transseptal PFO closure with Swartz SL1 Sheath: A safe and feasible approach for complex cases

article en

Abstract

Transcatheter closure of patent foramen ovale (PFO) has emerged as an effective therapeutic strategy, demonstrating superiority over medical treatment for patients with cryptogenic stroke (CS) or transient ischemic attack (TIA). This study aimed to evaluate the safety and feasibility of using intracardiac echocardiography (ICE) combined with the Swartz SL1 transseptal sheath for transcatheter PFO closure. This single-center study included consecutive patients with complex PFO, combined CS/TIA, and moderate to high levels of right-to-left shunt (RLS). Initial attempts to traverse the PFO were made using conventional methods; however, for cases where these attempts were unsuccessful, the PFO was subsequently traversed using the Swartz SL1 sheath under ICE and fluoroscopy guidance as a rescue strategy. Eighteen patients were enrolled, and the PFO was traversed using the Swartz SL1 sheath under ICE and fluoroscopy guidance. All procedures were performed under local anesthesia. The time required to traverse the PFO, total procedural duration, fluoroscopy time, and radiation dose were recorded. The mean time to traverse the interatrial septum was 1.62 [1.28–2.03] min, with a fluoroscopy duration of 0.97 [0.72–1.28] s. The total fluoroscopy duration and dose were 4.05 [3.16–6.53] min and 154.7 [57.0–280.0] mGy, respectively. The mean procedural duration was 28.3 ± 6.1 min. The combination of ICE and the Swartz SL1 transseptal sheath is a safe and efficient approach for transcatheter PFO closure, significantly reducing procedural time and radiation exposure compared to conventional methods, thereby enhancing safety. This approach may represent a safer and more efficient alternative to conventional methods, particularly in patients with complex PFO anatomy.

Journal of Radiation Research and Applied SciencesVol. 18(4)
Shanxi Medical University (CN), First Hospital of Shanxi Medical University (CN), Shanxi Cardiovascular Hospital (CN)
Good health and well-being
Openalex Percentile: Top 33%
Cardiovascular and Diving-Related Complications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.