Effect of luer-lock access device on hemolysis during blood collection via intravenous catheters in the emergency department

Abstract Objectives Emergency departments are the units where hemolysis is most frequently observed, and blood collection from intravenous catheters increases the hemolysis rate. This study aimed to compare the effects of two different blood collection methods from an intravenous catheter (an adapter and a syringe) on serum indices, complete blood count, and routine clinical chemistry tests in an emergency department. Methods The study encompassed 104 patients from the yellow and green zones of the Emergency Department at Canakkale Onsekiz Mart University Hospital. Blood samples were obtained from an intravenous catheter with a standard syringe and an adapter into serum separator tubes and dipotassium ethylenediaminetetraacetic acid (K 2 EDTA) tubes. Serum index, aspartate aminotransferase (AST), creatine kinase (CK), lactate dehydrogenase (LDH), potassium, high-sensitivity (hs) Troponin T, and complete blood count were evaluated. Passing-Bablok regression analysis was performed, and the mean percentage difference was calculated and compared to target values via a Bland-Altman plot. Results A statistically higher hemolysis rate was observed when blood was collected with a syringe, compared to collecting blood with an adapter (p<0.001). When the results were categorized according to the parameter-specific hemolysis index, AST, CK, potassium, LDH, and hs Troponin T results were more affected by hemolysis when blood was collected with a syringe (p<0.001). The mean percentage difference for AST and LDH exceeded the minimum target values based on biological variation. Conclusions Using a catheter-compatible adapter in emergency departments may reduce the rate of hemolysis and provide reliable results for tests frequently affected by hemolysis.

Institutions

Publication Details

Journal
Turkish Journal of Biochemistry
Published
2025-11-04
DOI
https://doi.org/10.1515/tjb-2025-0027
Primary Topic
Infection Control in Healthcare
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of luer-lock access device on hemolysis during blood collection via intravenous catheters in the emergency department

Turkish Journal of Biochemistry
Infection Control in Healthcare
article

Effect of luer-lock access device on hemolysis during blood collection via intravenous catheters in the emergency department

article en

Abstract

Abstract Objectives Emergency departments are the units where hemolysis is most frequently observed, and blood collection from intravenous catheters increases the hemolysis rate. This study aimed to compare the effects of two different blood collection methods from an intravenous catheter (an adapter and a syringe) on serum indices, complete blood count, and routine clinical chemistry tests in an emergency department. Methods The study encompassed 104 patients from the yellow and green zones of the Emergency Department at Canakkale Onsekiz Mart University Hospital. Blood samples were obtained from an intravenous catheter with a standard syringe and an adapter into serum separator tubes and dipotassium ethylenediaminetetraacetic acid (K 2 EDTA) tubes. Serum index, aspartate aminotransferase (AST), creatine kinase (CK), lactate dehydrogenase (LDH), potassium, high-sensitivity (hs) Troponin T, and complete blood count were evaluated. Passing-Bablok regression analysis was performed, and the mean percentage difference was calculated and compared to target values via a Bland-Altman plot. Results A statistically higher hemolysis rate was observed when blood was collected with a syringe, compared to collecting blood with an adapter (p<0.001). When the results were categorized according to the parameter-specific hemolysis index, AST, CK, potassium, LDH, and hs Troponin T results were more affected by hemolysis when blood was collected with a syringe (p<0.001). The mean percentage difference for AST and LDH exceeded the minimum target values based on biological variation. Conclusions Using a catheter-compatible adapter in emergency departments may reduce the rate of hemolysis and provide reliable results for tests frequently affected by hemolysis.

Turkish Journal of Biochemistry
Çanakkale Onsekiz Mart Üniversitesi (TR)
Openalex Percentile: Top 38%
Infection Control in Healthcare
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.