Abstract 4368616: Core lab versus computer: Pediatric echocardiogram measurement agreement between expert human and AI readers

Background: Deep learning algorithms for automated echocardiographic measurements have demonstrated strong performance in adult populations; however, their utility in pediatric echocardiography remains unclear. We evaluated the agreement between an FDA-approved software for automated adult echocardiogram measurements by Us2.ai and a pediatric core lab reader in assessing left ventricular (LV) size and function. Methods: We analyzed a retrospective dataset of pediatric echocardiogram DICOM files from 5 pediatric centers and corresponding core lab measurements collected from childhood cancer survivors under 21 years of age. The automated software processed the DICOM files, and agreement with core lab measurements for 17 2D and Doppler measurements was assessed using mean difference and intraclass correlation coefficient (ICC; two-way random effects, absolute agreement, single measures). Results: A total of 652 echocardiograms from 153 childhood cancer survivors were included. Median age at time of study was 13.4 (Q1 - Q3: 9.5 - 16.3) years, and 16% of studies showed depressed LV systolic function by core lab measurements (LV shortening fraction ≤28% or ejection fraction [EF] ≤50%). Table 1 summarizes the mean difference and ICC between the automated and core lab reader. Agreement was at least moderate (ICC > 0.5) across all variables. On average, the automated software underestimated biplane EF by 5 percentage points compared to the core lab reader with greater mean differences observed at higher EFs (-1 for core lab EF ≤ 50% and -5 for EF >50%; Figure 1). Conclusions: Independent validation of an automated echocardiographic measurement software in a pediatric dataset demonstrated at least moderate agreement of all measurements with gold-standard core lab measurements. The software exhibited a bias toward lower ejection fraction values; however, ICC for ejection fraction was comparable to previously reported interobserver variability among human pediatric readers.

Institutions

Publication Details

Journal
Circulation
Published
2025-11-03
DOI
https://doi.org/10.1161/circ.152.suppl_3.4368616
Primary Topic
Cardiovascular Function and Risk Factors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Abstract 4368616: Core lab versus computer: Pediatric echocardiogram measurement agreement between expert human and AI readers

Circulation
Cardiovascular Function and Risk Factors
article

Abstract 4368616: Core lab versus computer: Pediatric echocardiogram measurement agreement between expert human and AI readers

article en

Abstract

Background: Deep learning algorithms for automated echocardiographic measurements have demonstrated strong performance in adult populations; however, their utility in pediatric echocardiography remains unclear. We evaluated the agreement between an FDA-approved software for automated adult echocardiogram measurements by Us2.ai and a pediatric core lab reader in assessing left ventricular (LV) size and function. Methods: We analyzed a retrospective dataset of pediatric echocardiogram DICOM files from 5 pediatric centers and corresponding core lab measurements collected from childhood cancer survivors under 21 years of age. The automated software processed the DICOM files, and agreement with core lab measurements for 17 2D and Doppler measurements was assessed using mean difference and intraclass correlation coefficient (ICC; two-way random effects, absolute agreement, single measures). Results: A total of 652 echocardiograms from 153 childhood cancer survivors were included. Median age at time of study was 13.4 (Q1 - Q3: 9.5 - 16.3) years, and 16% of studies showed depressed LV systolic function by core lab measurements (LV shortening fraction ≤28% or ejection fraction [EF] ≤50%). Table 1 summarizes the mean difference and ICC between the automated and core lab reader. Agreement was at least moderate (ICC > 0.5) across all variables. On average, the automated software underestimated biplane EF by 5 percentage points compared to the core lab reader with greater mean differences observed at higher EFs (-1 for core lab EF ≤ 50% and -5 for EF >50%; Figure 1). Conclusions: Independent validation of an automated echocardiographic measurement software in a pediatric dataset demonstrated at least moderate agreement of all measurements with gold-standard core lab measurements. The software exhibited a bias toward lower ejection fraction values; however, ICC for ejection fraction was comparable to previously reported interobserver variability among human pediatric readers.

CirculationVol. 152(Suppl_3)
City Of Hope National Medical Center (US), Emory University (US), Duke University (US), University of Washington (US), University of Minnesota System (US), Hospital for Sick Children (CA), Fred Hutch Cancer Center (US), City of Hope (US)
Quality Education
Openalex Percentile: Top 35%
Cardiovascular Function and Risk Factors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.