Combined leadless pacing and subcutaneous defibrillation strategy in a high-risk patient: first case report from Peru

We present the case of a 51-year-old male with non-ischemic dilated cardiomyopathy and complete atrioventricular block, who was previously implanted with a cardiac resynchronization therapy defibrillator. The patient developed signs of pocket infection with a high risk of extrusion. Partial system extraction was performed, followed by 14 days of intravenous antibiotic therapy. Due to a history of ventricular fibrillation and permanent pacing dependency, and in the absence of viable transvenous access, a sequential implantation strategy was adopted using a leadless pacemaker (Micra AV, Medtronic) and a subcutaneous implantable cardioverter-defibrillator (EMBLEM, Boston Scientific). Both procedures were completed without complications, and the patient showed favorable recovery, with effective pacing, no arrhythmic recurrences, and no signs of infection at the six-month follow-up. This case illustrates the feasibility of a fully leadless approach in high-risk patients with contraindications to conventional transvenous systems.

Institutions

Publication Details

Journal
Archivos Peruanos de Cardiología y Cirugía Cardiovascular
Published
2025-10-18
DOI
https://doi.org/10.47487/apcyccv.v6i4.513
Primary Topic
Cardiac pacing and defibrillation studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Combined leadless pacing and subcutaneous defibrillation strategy in a high-risk patient: first case report from Peru

Archivos Peruanos de Cardiología y Cirugía Cardiovascular
Cardiac pacing and defibrillation studies
article

Combined leadless pacing and subcutaneous defibrillation strategy in a high-risk patient: first case report from Peru

article en

Abstract

We present the case of a 51-year-old male with non-ischemic dilated cardiomyopathy and complete atrioventricular block, who was previously implanted with a cardiac resynchronization therapy defibrillator. The patient developed signs of pocket infection with a high risk of extrusion. Partial system extraction was performed, followed by 14 days of intravenous antibiotic therapy. Due to a history of ventricular fibrillation and permanent pacing dependency, and in the absence of viable transvenous access, a sequential implantation strategy was adopted using a leadless pacemaker (Micra AV, Medtronic) and a subcutaneous implantable cardioverter-defibrillator (EMBLEM, Boston Scientific). Both procedures were completed without complications, and the patient showed favorable recovery, with effective pacing, no arrhythmic recurrences, and no signs of infection at the six-month follow-up. This case illustrates the feasibility of a fully leadless approach in high-risk patients with contraindications to conventional transvenous systems.

Archivos Peruanos de Cardiología y Cirugía CardiovascularVol. 6(4)
The Arrhythmia Institute (US), EsSALUD (PE)
Good health and well-being
Openalex Percentile: Top 36%
Cardiac pacing and defibrillation studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.