Determination of hydrogen peroxide in milk by fluorometric method using chitosan-coumarin film sensor

ABSTRACT: Accurate determination of hydrogen peroxide is of great importance from a public health standpoint. In this work, determination of hydrogen peroxide in milk was performed using chitosan-coumarin film sensor via a fluorometric method. Coumain-3-carboxylic acid (CCA) was used as a probe in the matrix of chitosan. The structures of the films were confirmed by various instrumental analysis including FT-IR, TGA, and SEM. Various parameters such as the amount of CCA, pH, and the effect of catalyst on the response of the sensor were investigated. The results indicated that ultraviolet radiation could improve the response of the sensor. Hydrogen peroxide was determined using this method in the range of 12-200 μM and 0.5-8.0 mM. The calibration plots demonstrated that the fluorescence response of the sensor films was linear over hydrogen peroxide concentrations of 12-200 µM and 500-8000 µM, with a detection limit (LOD) of 3 µM.

Institutions

Publication Details

Published
2025-09-26
DOI
https://doi.org/10.82397/jfbt.2025.1219222
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Determination of hydrogen peroxide in milk by fluorometric method using chitosan-coumarin film sensor

Electrochemical sensors and biosensors
article

Determination of hydrogen peroxide in milk by fluorometric method using chitosan-coumarin film sensor

article en

Abstract

ABSTRACT: Accurate determination of hydrogen peroxide is of great importance from a public health standpoint. In this work, determination of hydrogen peroxide in milk was performed using chitosan-coumarin film sensor via a fluorometric method. Coumain-3-carboxylic acid (CCA) was used as a probe in the matrix of chitosan. The structures of the films were confirmed by various instrumental analysis including FT-IR, TGA, and SEM. Various parameters such as the amount of CCA, pH, and the effect of catalyst on the response of the sensor were investigated. The results indicated that ultraviolet radiation could improve the response of the sensor. Hydrogen peroxide was determined using this method in the range of 12-200 μM and 0.5-8.0 mM. The calibration plots demonstrated that the fluorescence response of the sensor films was linear over hydrogen peroxide concentrations of 12-200 µM and 500-8000 µM, with a detection limit (LOD) of 3 µM.

Imam Khomeini International University (IR)
Openalex Percentile: Top 49%
Electrochemical sensors and biosensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.