DEVELOPMENT AND VALIDATION OF UV SPECTROSCOPIC METHOD FOR QUANTITATION OF VALSARTAN TABLET DOSAGE FORM

The UV spectroscopic method used to measure Tadalafilinvolves dissolving the drug in dichloromethane and thendiluting it with methanol. The absorbance of Tadalafil ismeasured at a wavelength of 284 nm, with methanol serving asthe reference. This method adheres to Beer‘s law within theconcentration range of 10 to 40 mcg/ml. The resulting linearequation is y = 0.01013x + 0.10100, and the correlationcoefficient is 0.99940. The UV spectroscopic method formeasuring Valsartan relies on determining the ultravioletabsorbance maximum of the drug at 230 nm, using acetonitrileas the diluent. The method follows Beer‘s law in theconcentration range of 2.5 to 25 mcg/ml, with the linearequation y = 0.05702x - 0.02740 and a correlation coefficientof 0.997. Additionally, the drug obeys Beer‘s law within theconcentration range of 2.5 to 15 mcg/ml. Both methods aresimple, fast, and do not involve complicated sample preparationsteps, making them economical and suitable for routine qualitycontrol applications. In conclusion, the developed methods are effective for the analysis ofthe selected drugs in both bulk and tablet forms.

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2025-10-29
DOI
https://doi.org/10.5281/zenodo.17471073
Primary Topic
Pharmaceutical Quality and Counterfeiting
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

DEVELOPMENT AND VALIDATION OF UV SPECTROSCOPIC METHOD FOR QUANTITATION OF VALSARTAN TABLET DOSAGE FORM

Zenodo (CERN European Organization for Nuclear Research)
Pharmaceutical Quality and Counterfeiting
article

DEVELOPMENT AND VALIDATION OF UV SPECTROSCOPIC METHOD FOR QUANTITATION OF VALSARTAN TABLET DOSAGE FORM

article en

Abstract

The UV spectroscopic method used to measure Tadalafilinvolves dissolving the drug in dichloromethane and thendiluting it with methanol. The absorbance of Tadalafil ismeasured at a wavelength of 284 nm, with methanol serving asthe reference. This method adheres to Beer‘s law within theconcentration range of 10 to 40 mcg/ml. The resulting linearequation is y = 0.01013x + 0.10100, and the correlationcoefficient is 0.99940. The UV spectroscopic method formeasuring Valsartan relies on determining the ultravioletabsorbance maximum of the drug at 230 nm, using acetonitrileas the diluent. The method follows Beer‘s law in theconcentration range of 2.5 to 25 mcg/ml, with the linearequation y = 0.05702x - 0.02740 and a correlation coefficientof 0.997. Additionally, the drug obeys Beer‘s law within theconcentration range of 2.5 to 15 mcg/ml. Both methods aresimple, fast, and do not involve complicated sample preparationsteps, making them economical and suitable for routine qualitycontrol applications. In conclusion, the developed methods are effective for the analysis ofthe selected drugs in both bulk and tablet forms.

Zenodo (CERN European Organization for Nuclear Research)
Openalex Percentile: Top 34%
Pharmaceutical Quality and Counterfeiting
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.