Prospective evaluation of pacemaker rate response in pediatric patients

Patients with chronotropic incompetence can benefit from permanent pacemakers (PPM) with rate responsive (RR) pacing. This feature employs an accelerometer and allows for heart rate (HR) adaptation based on sensed patient activity. Due to congenital heart disease (CHD) and other constraints, pediatric patients may have an epicardial pacing system with a generator implanted in the abdomen. No studies have investigated if the site of generator implantation impacts the functionality of RR pacing. The aim of this prospective study was to evaluate the difference in RR functionality of accelerometer-based pacemakers between patients with a generator placed in the abdomen versus thoracic location. Pediatric patients with a pacemaker implanted for complete heart block or sinus node dysfunction were enrolled. The pacemakers were temporarily reprogrammed to standardized RR parameters including activity thresholds, activity setpoints, and a HR range of 60–175 beats per minute. The participants then completed a standard Bruce protocol treadmill stress. HRs were measured at 30 second intervals. Ten pediatric patients with PPMs – five with abdominal and five with thoracic placement – were enrolled. No significant differences were found between the groups in age or exercise duration. There were no differences in the primary or secondary outcomes between the groups including HR change during exercise, maximum HR achieved, and time to maximum HR. PPM generator location does not seem to result in differences in RR functionality. These findings support individualized PPM programming and highlight the need for further pediatric-focused device research. • Pacemakers with rate response can benefit those with congenital heart disease. • The pacemaker may be placed in an atypical location in children. • No available data investigates how an abnormal location may affect function. • Preliminary data says there may be little difference, but more investigation is needed.

Institutions

Publication Details

Journal
Progress in Pediatric Cardiology
Published
2025-10-29
DOI
https://doi.org/10.1016/j.ppedcard.2025.101887
Primary Topic
Plant Taxonomy and Phylogenetics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Prospective evaluation of pacemaker rate response in pediatric patients

Progress in Pediatric Cardiology
Plant Taxonomy and Phylogenetics
article

Prospective evaluation of pacemaker rate response in pediatric patients

article en

Abstract

Patients with chronotropic incompetence can benefit from permanent pacemakers (PPM) with rate responsive (RR) pacing. This feature employs an accelerometer and allows for heart rate (HR) adaptation based on sensed patient activity. Due to congenital heart disease (CHD) and other constraints, pediatric patients may have an epicardial pacing system with a generator implanted in the abdomen. No studies have investigated if the site of generator implantation impacts the functionality of RR pacing. The aim of this prospective study was to evaluate the difference in RR functionality of accelerometer-based pacemakers between patients with a generator placed in the abdomen versus thoracic location. Pediatric patients with a pacemaker implanted for complete heart block or sinus node dysfunction were enrolled. The pacemakers were temporarily reprogrammed to standardized RR parameters including activity thresholds, activity setpoints, and a HR range of 60–175 beats per minute. The participants then completed a standard Bruce protocol treadmill stress. HRs were measured at 30 second intervals. Ten pediatric patients with PPMs – five with abdominal and five with thoracic placement – were enrolled. No significant differences were found between the groups in age or exercise duration. There were no differences in the primary or secondary outcomes between the groups including HR change during exercise, maximum HR achieved, and time to maximum HR. PPM generator location does not seem to result in differences in RR functionality. These findings support individualized PPM programming and highlight the need for further pediatric-focused device research. • Pacemakers with rate response can benefit those with congenital heart disease. • The pacemaker may be placed in an atypical location in children. • No available data investigates how an abnormal location may affect function. • Preliminary data says there may be little difference, but more investigation is needed.

Progress in Pediatric CardiologyVol. 79
St. Louis Children's Hospital (US), Washington University in St. Louis (US)
Openalex Percentile: Top 34%
Plant Taxonomy and Phylogenetics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.