Intraoperative Ultrasound in Chiari 1 Decompression: Clarity or Confusion? A Systematic Review.

Background And Objectives Patients with symptomatic Chiari malformation type 1 (CM-1) usually undergo either bone-only posterior fossa decompression (PFD) or a more invasive procedure involving dural expansion with or without tonsillar resection (PFD+). PFD+ may be more effective but it carries a higher risk of complications. Intraoperative ultrasound (iUS) may help determine whether PFD alone is sufficient, although specific criteria and its role in surgical decision making are not yet defined.Methods A systematic review was conducted following Preferred Reporting Items for Systematic Reviews and Meta-Analysis guidelines, using search terms related to iUS, intraoperative sonography, and CM-1. Extracted data included demographics, surgical methods, iUS criteria, and outcomes. Conversion rates and the positive predictive values (PPVs) were calculated to quantify iUS effectiveness. Conversion rate was defined as the proportion of cases requiring secondary PFD+ after initial PFD. PPV was based on the number of successful PFDs relative to all initial PFDs. Risk of bias was evaluated using the Newcastle-Ottawa scale.Results From 202 initial articles, 1 prospective and 8 retrospective studies were included, covering 844 pediatric and adult patients. According to the Newcastle-Ottawa scale, 1 study had a low, 3 moderate, and 5 high risk of bias. To assess decompression sufficiency, 8 studies used qualitative iUS criteria, whereas 1 used quantitative thresholds. Follow-up time ranged from 1 to 48 months, with varied outcome measures. Conversion rates ranged from 0% to 16% and PPV from 0.857 to 1.000, depending on the study. Conversion surgery rates were comparable with reoperation rates reported from studies without iUS.Conclusion The available evidence does not yet support iUS as a robust testing method to inform intraoperative decision making regarding the extent of decompression, due to the heterogeneity of its application, and the absence of standardized assessment criteria. We propose a reporting framework incorporating all currently reported criteria to induce standardization and guide further research.

Publication Details

Journal
Open Access CRIS of the University of Bern
Published
2025-10-23
DOI
https://doi.org/10.48620/92074
Primary Topic
solar cell performance optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Intraoperative Ultrasound in Chiari 1 Decompression: Clarity or Confusion? A Systematic Review.

Open Access CRIS of the University of Bern
solar cell performance optimization
article

Intraoperative Ultrasound in Chiari 1 Decompression: Clarity or Confusion? A Systematic Review.

article en

Abstract

Background And Objectives Patients with symptomatic Chiari malformation type 1 (CM-1) usually undergo either bone-only posterior fossa decompression (PFD) or a more invasive procedure involving dural expansion with or without tonsillar resection (PFD+). PFD+ may be more effective but it carries a higher risk of complications. Intraoperative ultrasound (iUS) may help determine whether PFD alone is sufficient, although specific criteria and its role in surgical decision making are not yet defined.Methods A systematic review was conducted following Preferred Reporting Items for Systematic Reviews and Meta-Analysis guidelines, using search terms related to iUS, intraoperative sonography, and CM-1. Extracted data included demographics, surgical methods, iUS criteria, and outcomes. Conversion rates and the positive predictive values (PPVs) were calculated to quantify iUS effectiveness. Conversion rate was defined as the proportion of cases requiring secondary PFD+ after initial PFD. PPV was based on the number of successful PFDs relative to all initial PFDs. Risk of bias was evaluated using the Newcastle-Ottawa scale.Results From 202 initial articles, 1 prospective and 8 retrospective studies were included, covering 844 pediatric and adult patients. According to the Newcastle-Ottawa scale, 1 study had a low, 3 moderate, and 5 high risk of bias. To assess decompression sufficiency, 8 studies used qualitative iUS criteria, whereas 1 used quantitative thresholds. Follow-up time ranged from 1 to 48 months, with varied outcome measures. Conversion rates ranged from 0% to 16% and PPV from 0.857 to 1.000, depending on the study. Conversion surgery rates were comparable with reoperation rates reported from studies without iUS.Conclusion The available evidence does not yet support iUS as a robust testing method to inform intraoperative decision making regarding the extent of decompression, due to the heterogeneity of its application, and the absence of standardized assessment criteria. We propose a reporting framework incorporating all currently reported criteria to induce standardization and guide further research.

Open Access CRIS of the University of Bern
Peace, Justice and strong institutions
Openalex Percentile: Top 49%
solar cell performance optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Intraoperative Ultrasound in Chiari 1 Decompression: Clarity or Confusion? A Systematic Review. · Open Access CRIS of the University of Bern (2025) | TGRS Research Map | TGRS