Analysis on performance of zero sequence signal based single phase ground fault detection method to identify line broken fault

Single phase ground (SPG) faults detection method based on zero-sequence signal (ZSS) are widely used in non-effectively grounded distribution networks. However, their performance in detecting single phase line broken (SPLB) faults is not yet clear. This paper studies the potential dead zone when ZSS-based SPG fault detection method is used to detect SPLB faults. Firstly, equations for the steady-state zero sequence voltage (ZSV) on both sides of the fault point under various SPLB fault conditions are derived. Next, the dead zone of the start-up criterion based on steady-state ZSV is studied. Subsequently, the zero sequence networks under different SPLB fault conditions are built, and then the relation-ship between transient ZSV and zero sequence current (ZSC) under different SPLB fault conditions is analysed and the dead zone of transient ZSS-based SPG fault detection methods for SPLB faults identification is examined. Finally, PSCAD simulations are performed and the accuracy of the theoretical analysis is validated.

Institutions

Publication Details

Journal
IET conference proceedings.
Published
2025-10-01
DOI
https://doi.org/10.1049/icp.2025.3225
Primary Topic
Management and Marketing Education
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis on performance of zero sequence signal based single phase ground fault detection method to identify line broken fault

IET conference proceedings.
Management and Marketing Education
article

Analysis on performance of zero sequence signal based single phase ground fault detection method to identify line broken fault

article en

Abstract

Single phase ground (SPG) faults detection method based on zero-sequence signal (ZSS) are widely used in non-effectively grounded distribution networks. However, their performance in detecting single phase line broken (SPLB) faults is not yet clear. This paper studies the potential dead zone when ZSS-based SPG fault detection method is used to detect SPLB faults. Firstly, equations for the steady-state zero sequence voltage (ZSV) on both sides of the fault point under various SPLB fault conditions are derived. Next, the dead zone of the start-up criterion based on steady-state ZSV is studied. Subsequently, the zero sequence networks under different SPLB fault conditions are built, and then the relation-ship between transient ZSV and zero sequence current (ZSC) under different SPLB fault conditions is analysed and the dead zone of transient ZSS-based SPG fault detection methods for SPLB faults identification is examined. Finally, PSCAD simulations are performed and the accuracy of the theoretical analysis is validated.

IET conference proceedings.Vol. 2025(26)
Xi'an Jiaotong University (CN)
Climate action
Openalex Percentile: Top 34%
Management and Marketing Education
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Analysis on performance of zero sequence signal based single phase ground fault detection method to identify line broken fault · IET conference proceedings. (2025) | TGRS Research Map | TGRS