Simulation study on control system parameter optimization for suppressing transient voltage rise at new energy generator terminals in DC near-zones of weak-resource power systems

From the perspective of grid-following control system mechanism, this paper conducts theoretical analysis and supplementary simulation studies on DC control systems, new energy generation control systems, and reactive power compensation devices that influence transient voltage rise. The rectifier current control loop, voltage-dependent current order limiter (VDCOL) link, and commutation failure prediction function loop in DC control systems are identified as the primary control elements affecting the commutation failure recovery process. The control strategy optimization achieves comparable voltage suppression performance to synchronous condensers but with 80%-85% lower configuration costs. This approach serves as a cost-effective alternative to rotating equipment, particularly suitable for large-scale new energy DC transmission systems where transient voltage rise suppression and economic efficiency are both prioritized.

Institutions

Publication Details

Journal
IET conference proceedings.
Published
2025-10-01
DOI
https://doi.org/10.1049/icp.2025.3220
Primary Topic
HVDC Systems and Fault Protection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Simulation study on control system parameter optimization for suppressing transient voltage rise at new energy generator terminals in DC near-zones of weak-resource power systems

IET conference proceedings.
HVDC Systems and Fault Protection
article

Simulation study on control system parameter optimization for suppressing transient voltage rise at new energy generator terminals in DC near-zones of weak-resource power systems

article en

Abstract

From the perspective of grid-following control system mechanism, this paper conducts theoretical analysis and supplementary simulation studies on DC control systems, new energy generation control systems, and reactive power compensation devices that influence transient voltage rise. The rectifier current control loop, voltage-dependent current order limiter (VDCOL) link, and commutation failure prediction function loop in DC control systems are identified as the primary control elements affecting the commutation failure recovery process. The control strategy optimization achieves comparable voltage suppression performance to synchronous condensers but with 80%-85% lower configuration costs. This approach serves as a cost-effective alternative to rotating equipment, particularly suitable for large-scale new energy DC transmission systems where transient voltage rise suppression and economic efficiency are both prioritized.

IET conference proceedings.Vol. 2025(26)
Shanghai Electric (China) (CN), Shanghai University of International Business and Economics (CN)
Decent work and economic growth
Openalex Percentile: Top 49%
HVDC Systems and Fault Protection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Simulation study on control system parameter optimization for suppressing transient voltage rise at new energy generator terminals in DC near-zones of weak-resource power systems · IET conference proceedings. (2025) | TGRS Research Map | TGRS