Analytical Method Development and Validation for Estimation of Safinamide Mesylate by RP-HPLC in Bulk Drug and Pharmaceutical Dosage Form

A new, accurate and precise High performance liquid chromatography method have been developed for the estimation of Safinamide Mesylate in bulk drug and pharmaceutical dosage form. The chromatographic separation was carried out on Agilent poroshell C18 (150 mm X 4.6 mm i.d.) 5μm column using a mixture of Acetonitrile: 0.1% TFAA in Water (70:30) as a mobile phase at a flow rate of 1.0 ml/min, the detection as carried out at 226 nm. The retention time of Safinamide Mesylate was 2.63 respectively. The method produced linear responses in the concentration range of 15.0 -45.0 μg/ml of Safinamide Mesylate. The LOD and LOQ was found to be LOD = 0.259 µg/mL and LOQ = 0.785 µg/mL for Safinamide Mesylate respectively. The accuracy of method was validated by recovery studies and found to be significant within acceptable range 98.0-102.0%. The developed RP-HPLC method is found to be accurate, precise, linear and robust. The present work is successfully developed and validated as per ICH guidelines. The proposed method provides accurate and precise quality control tool for routine of Safinamide Mesylate in bulk and in pharmaceutical dosage form.

Institutions

Publication Details

Journal
Asian Journal of Pharmaceutical Analysis
Published
2025-10-08
DOI
https://doi.org/10.52711/2231-5675.2025.00047
Primary Topic
Analytical Methods in Pharmaceuticals
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analytical Method Development and Validation for Estimation of Safinamide Mesylate by RP-HPLC in Bulk Drug and Pharmaceutical Dosage Form

Asian Journal of Pharmaceutical Analysis
Analytical Methods in Pharmaceuticals
article

Analytical Method Development and Validation for Estimation of Safinamide Mesylate by RP-HPLC in Bulk Drug and Pharmaceutical Dosage Form

article en

Abstract

A new, accurate and precise High performance liquid chromatography method have been developed for the estimation of Safinamide Mesylate in bulk drug and pharmaceutical dosage form. The chromatographic separation was carried out on Agilent poroshell C18 (150 mm X 4.6 mm i.d.) 5μm column using a mixture of Acetonitrile: 0.1% TFAA in Water (70:30) as a mobile phase at a flow rate of 1.0 ml/min, the detection as carried out at 226 nm. The retention time of Safinamide Mesylate was 2.63 respectively. The method produced linear responses in the concentration range of 15.0 -45.0 μg/ml of Safinamide Mesylate. The LOD and LOQ was found to be LOD = 0.259 µg/mL and LOQ = 0.785 µg/mL for Safinamide Mesylate respectively. The accuracy of method was validated by recovery studies and found to be significant within acceptable range 98.0-102.0%. The developed RP-HPLC method is found to be accurate, precise, linear and robust. The present work is successfully developed and validated as per ICH guidelines. The proposed method provides accurate and precise quality control tool for routine of Safinamide Mesylate in bulk and in pharmaceutical dosage form.

Asian Journal of Pharmaceutical Analysis
Sanskriti Samvardhan Mandal (IN)
Openalex Percentile: Top 48%
Analytical Methods in Pharmaceuticals
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.