Analytical Method Development and Validation for Estimation of Fimasartan in Bulk Drug and Pharmaceutical Dosage Form

A research presents the development and validation of a reliable and robust reverse-phase high-performance liquid chromatography (RP-HPLC) method for the quantitative estimation of Fimasartan in pharmaceutical tablet formulations. Fimasartan, a selective non-peptide angiotensin II type 1 (AT1) receptor blocker, is widely prescribed for managing essential hypertension. Regulatory standards. The method employed a Phenomenex C18 column under isocratic conditions, using a mobile phase consisting of acetonitrile and 0.05% orthophosphoric acid in water in a 75:25 (v/v) ratio. Chromatographic separation was achieved at a flow rate of 1.0 mL/min, with UV detection at 262 nm. The method exhibited excellent linearity within the concentration range of 10.0–30.0 µg/mL, with a correlation coefficient (R²) of 0.99998. The limits of detection (LOD) and quantification (LOQ) were found to be 0.156 µg/mL and 0.472 µg/mL, respectively. Validation, carried out according to ICH Q2(R1) guidelines, confirmed the method’s accuracy, with recovery results ranging from 98.90% to 100.89%. The method also demonstrated high precision (%RSD < 1.5), specificity, and robustness when subjected to deliberate variations in chromatographic parameters. Stability studies confirmed that sample solutions remained stable for at least 24 hours, while filtration tests indicated no significant analyte loss when using PVDF or nylon syringe filters. The validated method was successfully applied for the assay of commercially marketed Fimasartan tablets (Fimagen 60 mg), delivering consistent and reproducible outcomes. Overall, the proposed RP-HPLC method is simple, rapid, and highly suitable for routine quality control and analysis of Fimasartan in both bulk and finished dosage forms.

Institutions

Publication Details

Journal
Asian Journal of Pharmaceutical Analysis
Published
2025-10-08
DOI
https://doi.org/10.52711/2231-5675.2025.00039
Primary Topic
Research Data Management Practices
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analytical Method Development and Validation for Estimation of Fimasartan in Bulk Drug and Pharmaceutical Dosage Form

Asian Journal of Pharmaceutical Analysis
Research Data Management Practices
article

Analytical Method Development and Validation for Estimation of Fimasartan in Bulk Drug and Pharmaceutical Dosage Form

article en

Abstract

A research presents the development and validation of a reliable and robust reverse-phase high-performance liquid chromatography (RP-HPLC) method for the quantitative estimation of Fimasartan in pharmaceutical tablet formulations. Fimasartan, a selective non-peptide angiotensin II type 1 (AT1) receptor blocker, is widely prescribed for managing essential hypertension. Regulatory standards. The method employed a Phenomenex C18 column under isocratic conditions, using a mobile phase consisting of acetonitrile and 0.05% orthophosphoric acid in water in a 75:25 (v/v) ratio. Chromatographic separation was achieved at a flow rate of 1.0 mL/min, with UV detection at 262 nm. The method exhibited excellent linearity within the concentration range of 10.0–30.0 µg/mL, with a correlation coefficient (R²) of 0.99998. The limits of detection (LOD) and quantification (LOQ) were found to be 0.156 µg/mL and 0.472 µg/mL, respectively. Validation, carried out according to ICH Q2(R1) guidelines, confirmed the method’s accuracy, with recovery results ranging from 98.90% to 100.89%. The method also demonstrated high precision (%RSD < 1.5), specificity, and robustness when subjected to deliberate variations in chromatographic parameters. Stability studies confirmed that sample solutions remained stable for at least 24 hours, while filtration tests indicated no significant analyte loss when using PVDF or nylon syringe filters. The validated method was successfully applied for the assay of commercially marketed Fimasartan tablets (Fimagen 60 mg), delivering consistent and reproducible outcomes. Overall, the proposed RP-HPLC method is simple, rapid, and highly suitable for routine quality control and analysis of Fimasartan in both bulk and finished dosage forms.

Asian Journal of Pharmaceutical Analysis
Sanskriti Samvardhan Mandal (IN)
Clean water and sanitation
Openalex Percentile: Top 33%
Research Data Management Practices
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.