Advancing Crystallography Research: The Latest Progress and Future Directions of NE-CAT Beamlines at the Advanced Photon Source

The Northeastern Collaborative Access Team (NE-CAT) develops and operates advanced synchrotron X-ray beamlines to support high-impact structural biology research. With specialized instrumentation and deep expertise, NE-CAT serves a global user base, facilitating structural determination of challenging macromolecular systems. Following the completion of the Advanced Photon Source (APS) upgrade, NE-CAT has implemented key improvements to ensure optimal performance, flexibility, and reliability in data collection. These include a high- speed storage infrastructure and the deployment of RAPDv2—a next-generation data processing suite that offers seamless integration, scalable performance, and automated workflows for molecular replacement (MR) and single- wavelength anomalous dispersion (SAD) experiments. Ongoing developments include the installation of a new monochromator for beamline 24-ID-C, the integration of MD3 micro-diffractometers for enhanced precision, and the deployment of a custom-built automounter capable of holding 30 sample pucks. Additionally, we are introducing an upgraded remote user interface to enable fully automated data collection and expanding support for room-temperature data acquisition experiments. Currently, NE-CAT operates beamline 24-ID-E, a fixed-energy (12.662 keV) undulator beamline optimized for remote use. It’s equipped with an MD2 micro-diffractometer, ALS-style 14-puck automounters, and the RAPDv2 platform. NE-CAT offers 24/7 user support and secure, flexible data access through Globus or a custom Python sync script. Beamline 24-ID-C is under development and will soon launch with fully redesigned systems and enhanced capabilities. NE-CAT is funded by a P30 grant from the National Institute of General Medical Sciences (NIGMS), with additional support from member institutions. We welcome collaboration and community input as we continue advancing resources to meet the evolving needs of structural biology.

Institutions

Publication Details

Journal
Structural Dynamics
Published
2025-09-01
DOI
https://doi.org/10.1063/4.0001123
Primary Topic
Erythrocyte Function and Pathophysiology
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Advancing Crystallography Research: The Latest Progress and Future Directions of NE-CAT Beamlines at the Advanced Photon Source

Structural Dynamics
Erythrocyte Function and Pathophysiology
article

Advancing Crystallography Research: The Latest Progress and Future Directions of NE-CAT Beamlines at the Advanced Photon Source

article en

Abstract

The Northeastern Collaborative Access Team (NE-CAT) develops and operates advanced synchrotron X-ray beamlines to support high-impact structural biology research. With specialized instrumentation and deep expertise, NE-CAT serves a global user base, facilitating structural determination of challenging macromolecular systems. Following the completion of the Advanced Photon Source (APS) upgrade, NE-CAT has implemented key improvements to ensure optimal performance, flexibility, and reliability in data collection. These include a high- speed storage infrastructure and the deployment of RAPDv2—a next-generation data processing suite that offers seamless integration, scalable performance, and automated workflows for molecular replacement (MR) and single- wavelength anomalous dispersion (SAD) experiments. Ongoing developments include the installation of a new monochromator for beamline 24-ID-C, the integration of MD3 micro-diffractometers for enhanced precision, and the deployment of a custom-built automounter capable of holding 30 sample pucks. Additionally, we are introducing an upgraded remote user interface to enable fully automated data collection and expanding support for room-temperature data acquisition experiments. Currently, NE-CAT operates beamline 24-ID-E, a fixed-energy (12.662 keV) undulator beamline optimized for remote use. It’s equipped with an MD2 micro-diffractometer, ALS-style 14-puck automounters, and the RAPDv2 platform. NE-CAT offers 24/7 user support and secure, flexible data access through Globus or a custom Python sync script. Beamline 24-ID-C is under development and will soon launch with fully redesigned systems and enhanced capabilities. NE-CAT is funded by a P30 grant from the National Institute of General Medical Sciences (NIGMS), with additional support from member institutions. We welcome collaboration and community input as we continue advancing resources to meet the evolving needs of structural biology.

Structural DynamicsVol. 12(5_Supplement)
Cornell University (US)
Industry, innovation and infrastructure
Openalex Percentile: Top 40%
Erythrocyte Function and Pathophysiology
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.