Avoidance distance analysis based on HVDC transient magnetic field and grounding current additional magnetic field

High Voltage Direct Current (HVDC) transmission disturbs geomagnetic observations not only through overhead line currents, but also via the additional Magnetic Fields (MF) introduced by the transient MF and the grounding current. Mechanistic calculation reveals that the additional MF generated by the transient MF contributes to interference both in the vertical and horizontal directions, while the additional MF generated by grounding current primarily affects the horizontal direction. Both interference sources exhibit lower amplitude compared to the direct MF generated by overhead line currents. Practical case studies indicate that the interference of the additional MF generated by the grounding current can be mitigated through spatial avoidance: to reduce the interference amplitude below 0.5nT, an observation station should be positioned at least 30km from the grounding point, while complete absence of interference requires a minimum distance of 60km.

Institutions

Publication Details

Journal
IET conference proceedings.
Published
2025-10-01
DOI
https://doi.org/10.1049/icp.2025.3242
Primary Topic
Lightning and Electromagnetic Phenomena
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Avoidance distance analysis based on HVDC transient magnetic field and grounding current additional magnetic field

IET conference proceedings.
Lightning and Electromagnetic Phenomena
article

Avoidance distance analysis based on HVDC transient magnetic field and grounding current additional magnetic field

article en

Abstract

High Voltage Direct Current (HVDC) transmission disturbs geomagnetic observations not only through overhead line currents, but also via the additional Magnetic Fields (MF) introduced by the transient MF and the grounding current. Mechanistic calculation reveals that the additional MF generated by the transient MF contributes to interference both in the vertical and horizontal directions, while the additional MF generated by grounding current primarily affects the horizontal direction. Both interference sources exhibit lower amplitude compared to the direct MF generated by overhead line currents. Practical case studies indicate that the interference of the additional MF generated by the grounding current can be mitigated through spatial avoidance: to reduce the interference amplitude below 0.5nT, an observation station should be positioned at least 30km from the grounding point, while complete absence of interference requires a minimum distance of 60km.

IET conference proceedings.Vol. 2025(26)
Heilongjiang Earthquake Agency (CN), National Earthquake Response Support Service (CN), China Earthquake Administration (CN)
Openalex Percentile: Top 46%
Lightning and Electromagnetic Phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.