Gradient Pre-Emphasis Calibration

Abstract A common problem since the early development of MRI systems, which persists to this day, is the induction of eddy currents (EC) in the conductive parts of the MR scanner during the rise and decay of gradient pulses. The magnitude of the eddy currents, among other factors, is proportional to the magnitude of the gradient pulses and the magnitude of change in the gradient field over time. These eddy currents cause several problems, ranging from heating of the cryostat to undesirable time-varying gradient fields that produce various artefacts in the acquired images or undesirable effects on tissue structures in patients. There are several ways to suppress the eddy current effect. In this article, we focus on eddy current compensation by modulating gradient pre-emphasis.

Institutions

Publication Details

Journal
Measurement Science Review
Published
2025-10-01
DOI
https://doi.org/10.2478/msr-2025-0032
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Gradient Pre-Emphasis Calibration

Measurement Science Review
Advanced MRI Techniques and Applications
article

Gradient Pre-Emphasis Calibration

article en

Abstract

Abstract A common problem since the early development of MRI systems, which persists to this day, is the induction of eddy currents (EC) in the conductive parts of the MR scanner during the rise and decay of gradient pulses. The magnitude of the eddy currents, among other factors, is proportional to the magnitude of the gradient pulses and the magnitude of change in the gradient field over time. These eddy currents cause several problems, ranging from heating of the cryostat to undesirable time-varying gradient fields that produce various artefacts in the acquired images or undesirable effects on tissue structures in patients. There are several ways to suppress the eddy current effect. In this article, we focus on eddy current compensation by modulating gradient pre-emphasis.

Measurement Science ReviewVol. 25(5)
Institute of Measurement Science of the Slovak Academy of Sciences (SK)
Openalex Percentile: Top 36%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Gradient Pre-Emphasis Calibration · Measurement Science Review (2025) | TGRS Research Map | TGRS