Development and Validation of Quality by Design‐Based HPLC Method for Impurity Profiling of Alprazolam

ABSTRACT A quality by design (QbD)‐aided stability‐indicating method was developed for the simultaneous quantification of alprazolam and its four impurities using HPLC. The method was systematically optimized, followed by the establishment of a “method operable design region (MODR).” Critical parameters and ICH (Q14) emphasize the adherence to a “low‐risk approach” as per “USP 1210” and compliance with it. Chromatographic separation was achieved using a Poroshell 120 phenyl hexyl column (100 mm × 4.6 mm, 2.7 µm) and measured at 254 nm. The composition of Mobile Phase A was 44:56 vol/vol buffer (pH 3.5) and methanol, whereas Mobile Phase B had 5:95 vol/vol buffer (pH 3.5) and methanol in gradient elution mode (Time/%A—0/98, 6/98, 14/1, 16/1, 18/98, 22/98) at a flow rate of 1.0 mL/min and an injection volume of 10 µL. Forced degradation studies were conducted, where no significant degradation product peaks were observed under any degradation conditions. The developed method was validated as per ICH (Q2(R2)) guidelines. The method exhibited good linearity, as correlation coefficient ( r 2 ) values for all analytes range from 0.976 to 0.986. %RSD values in precision studies were within the acceptance criteria (<15%). The %RSD values for six replicate injections at the LOQ level for these impurities range from 0.9% to 4.3%. In the combined study of validation of accuracy and precision as per USP 〈1210〉 guidelines, the computed interval bounds for all impurities were within the specified limits of 95%–105%, ensuring the method's robustness. The recovery values in the accuracy study ranged from 98.9% to 101.8% across all impurities. The tolerance interval analysis, performed at a 95% confidence level with 5% alpha, confirmed that the computed intervals for all impurities fell within the specification limits. Collectively, these results demonstrate that the method is a low‐risk approach, and the developed method is suitable for routine quality control in pharmaceutical manufacturing.

Institutions

Publication Details

Journal
Separation Science Plus
Published
2025-10-01
DOI
https://doi.org/10.1002/sscp.70147
Primary Topic
Analytical Methods in Pharmaceuticals
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development and Validation of Quality by Design‐Based HPLC Method for Impurity Profiling of Alprazolam

Separation Science Plus
Analytical Methods in Pharmaceuticals
article

Development and Validation of Quality by Design‐Based HPLC Method for Impurity Profiling of Alprazolam

article en

Abstract

ABSTRACT A quality by design (QbD)‐aided stability‐indicating method was developed for the simultaneous quantification of alprazolam and its four impurities using HPLC. The method was systematically optimized, followed by the establishment of a “method operable design region (MODR).” Critical parameters and ICH (Q14) emphasize the adherence to a “low‐risk approach” as per “USP 1210” and compliance with it. Chromatographic separation was achieved using a Poroshell 120 phenyl hexyl column (100 mm × 4.6 mm, 2.7 µm) and measured at 254 nm. The composition of Mobile Phase A was 44:56 vol/vol buffer (pH 3.5) and methanol, whereas Mobile Phase B had 5:95 vol/vol buffer (pH 3.5) and methanol in gradient elution mode (Time/%A—0/98, 6/98, 14/1, 16/1, 18/98, 22/98) at a flow rate of 1.0 mL/min and an injection volume of 10 µL. Forced degradation studies were conducted, where no significant degradation product peaks were observed under any degradation conditions. The developed method was validated as per ICH (Q2(R2)) guidelines. The method exhibited good linearity, as correlation coefficient ( r 2 ) values for all analytes range from 0.976 to 0.986. %RSD values in precision studies were within the acceptance criteria (<15%). The %RSD values for six replicate injections at the LOQ level for these impurities range from 0.9% to 4.3%. In the combined study of validation of accuracy and precision as per USP 〈1210〉 guidelines, the computed interval bounds for all impurities were within the specified limits of 95%–105%, ensuring the method's robustness. The recovery values in the accuracy study ranged from 98.9% to 101.8% across all impurities. The tolerance interval analysis, performed at a 95% confidence level with 5% alpha, confirmed that the computed intervals for all impurities fell within the specification limits. Collectively, these results demonstrate that the method is a low‐risk approach, and the developed method is suitable for routine quality control in pharmaceutical manufacturing.

Separation Science PlusVol. 8(10)
Government of Andhra Pradesh (IN), Research Institute for Chromatography (BE), GITAM University (IN)
Openalex Percentile: Top 48%
Analytical Methods in Pharmaceuticals
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Development and Validation of Quality by Design‐Based HPLC Method for Impurity Profiling of Alprazolam · Separation Science Plus (2025) | TGRS Research Map | TGRS