Horizontal light pipe system for daylight optimization in deep-plan library spaces in a tropical climate

Deep-plan spaces, such as a library reading area, typically suffer from poor daylight penetration to the core, which reduces visual comfort and increases dependence on artificial lighting. Horizontal Light Pipes (HLPs) are a passive daylighting system that captures daylight through an inlet and transports it through a reflective pipe before distributing it into the interior. This research examines the performance of HLPs in the second-floor reading room of a university’s Central Library, a typical institutional building in a tropical climate. Field measurements of illuminance were carried out to record existing conditions and were later used to validate ClimateStudio simulation results. A Rhino and Grasshopper parametric workflow defined six HLP geometry variables and generated different HLP configurations for ClimateStudio analysis. Multi-objective optimization was performed using the Octopus plug-in to identify the most effective solutions, evaluating 1,100 genomes. Data export and organization were managed through the TT toolbox, and results were analyzed using statistical methods and cross-checked with Design Explorer. Performance was evaluated using daylighting and energy metrics such as mean illuminance, spatial daylight autonomy (sDA300/50%), annual sunlight exposure (ASE1000,250h), and energy use intensity (EUI). Compared with the base case with mean illuminance 393 lux, sDA300/50% of 38.4%, ASE1000,250h of 3.4%, EUI of 83.17 kWh/(m2y), HLP integrated optimized models achieved mean illuminance 760~880 lux with sDA300/50% of 77.33~80.12%, ASE1000,250h of 0.62~0.93% and EUI 71.02~71.13 kWh/(m2y), showing significant improvement over the base case. These results suggest that HLPs can provide better daylight distribution and reduce energy usage in deep-plan libraries. According to the study, HLPs have the potential to be a practical strategy for improving daylight performance in tropical academic buildings.

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2025-10-26
DOI
https://doi.org/10.5281/zenodo.17447843
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Horizontal light pipe system for daylight optimization in deep-plan library spaces in a tropical climate

Zenodo (CERN European Organization for Nuclear Research)
Building Energy and Comfort Optimization
article

Horizontal light pipe system for daylight optimization in deep-plan library spaces in a tropical climate

article en

Abstract

Deep-plan spaces, such as a library reading area, typically suffer from poor daylight penetration to the core, which reduces visual comfort and increases dependence on artificial lighting. Horizontal Light Pipes (HLPs) are a passive daylighting system that captures daylight through an inlet and transports it through a reflective pipe before distributing it into the interior. This research examines the performance of HLPs in the second-floor reading room of a university’s Central Library, a typical institutional building in a tropical climate. Field measurements of illuminance were carried out to record existing conditions and were later used to validate ClimateStudio simulation results. A Rhino and Grasshopper parametric workflow defined six HLP geometry variables and generated different HLP configurations for ClimateStudio analysis. Multi-objective optimization was performed using the Octopus plug-in to identify the most effective solutions, evaluating 1,100 genomes. Data export and organization were managed through the TT toolbox, and results were analyzed using statistical methods and cross-checked with Design Explorer. Performance was evaluated using daylighting and energy metrics such as mean illuminance, spatial daylight autonomy (sDA300/50%), annual sunlight exposure (ASE1000,250h), and energy use intensity (EUI). Compared with the base case with mean illuminance 393 lux, sDA300/50% of 38.4%, ASE1000,250h of 3.4%, EUI of 83.17 kWh/(m2y), HLP integrated optimized models achieved mean illuminance 760~880 lux with sDA300/50% of 77.33~80.12%, ASE1000,250h of 0.62~0.93% and EUI 71.02~71.13 kWh/(m2y), showing significant improvement over the base case. These results suggest that HLPs can provide better daylight distribution and reduce energy usage in deep-plan libraries. According to the study, HLPs have the potential to be a practical strategy for improving daylight performance in tropical academic buildings.

Zenodo (CERN European Organization for Nuclear Research)
Bangladesh University of Engineering and Technology (BD)
Climate action
Openalex Percentile: Top 47%
Building Energy and Comfort Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Horizontal light pipe system for daylight optimization in deep-plan library spaces in a tropical climate · Zenodo (CERN European Organization for Nuclear Research) (2025) | TGRS Research Map | TGRS