Late Spontaneous in-the-Bag Capsular Tension Ring - Intraocular Lens - Capsular Bag Complex Subluxation in a Low-PEX Region: A Series of 31 Cases

Xiaomin Liu,1– 3 Xin Liu,1 Yingli Teng,1 Jun Li,1– 3 Yan Gao,1– 3 Xiubin Ma1– 3 1Qingdao Eye Hospital of Shandong First Medical University, Qingdao, Shandong, People’s Republic of China; 2State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, Qingdao, Shandong, People’s Republic of China; 3Department of Ophthalmology, School of Ophthalmology, Shandong First Medical University, Qingdao, Shandong, People’s Republic of ChinaCorrespondence: Xiubin Ma, Qingdao Eye Hospital of Shandong First Medical University, Qingdao, 266071, People’s Republic of China, Tel +86-0532-85876380, Email [email protected]: To evaluate the incidence, risk factors, and surgical management of CTR-IOL-CB complex subluxation/dislocation in a low-pseudoexfoliation area.Methods: Patients with CTR-IOL-CB complex subluxation/dislocation who had complete medical records at the Qingdao Eye Hospital of Shandong First Medical University between January 1994 and April 2024 were selected. Patient demographic data, incidence, interval, risk factors, extent of zonular weakness, IOL and CTR design and material, surgical management, visual acuity (VA), and other complications.Results: 31 cases aged 65.17 ± 7.19 years at CTR-IOL-CB complex subluxation/dislocation were reviewed; the interval was 41.23 ± 14.63 months after implantation of IOL and CTR. The incidence rate of CTR-IOL-CB complex subluxation/dislocation was 0.85%. The most common risk factors were ocular trauma and hypermature cataract. Extent of zonular weakness of ≥ 4 o’clock and the use of 1-piece hydrophilic acrylic and 3-piece hydrophobic acrylic IOLs were susceptible to complex subluxation/dislocation. VA was significantly increased after IOL repositioning or exchange; no other complications were present.Conclusion: Zonular insufficiency stabilized with IOL and CTR alone still carries a risk of re-dislocation. Ocular trauma and hypermature cataract were the most common risks in a low-pseudoexfoliation region. IOL exchange or repositioning is effective for this complication.Keywords: CTR-IOL-CB complex, subluxation/dislocation, incidence, zonule weakness, surgical management

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2025-10-01
Primary Topic
Music Technology and Sound Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Late Spontaneous in-the-Bag Capsular Tension Ring - Intraocular Lens - Capsular Bag Complex Subluxation in a Low-PEX Region: A Series of 31 Cases

SHILAP Revista de lepidopterología
Music Technology and Sound Studies
article

Late Spontaneous in-the-Bag Capsular Tension Ring - Intraocular Lens - Capsular Bag Complex Subluxation in a Low-PEX Region: A Series of 31 Cases

article en

Abstract

Xiaomin Liu,1– 3 Xin Liu,1 Yingli Teng,1 Jun Li,1– 3 Yan Gao,1– 3 Xiubin Ma1– 3 1Qingdao Eye Hospital of Shandong First Medical University, Qingdao, Shandong, People’s Republic of China; 2State Key Laboratory Cultivation Base, Shandong Provincial Key Laboratory of Ophthalmology, Qingdao, Shandong, People’s Republic of China; 3Department of Ophthalmology, School of Ophthalmology, Shandong First Medical University, Qingdao, Shandong, People’s Republic of ChinaCorrespondence: Xiubin Ma, Qingdao Eye Hospital of Shandong First Medical University, Qingdao, 266071, People’s Republic of China, Tel +86-0532-85876380, Email [email protected]: To evaluate the incidence, risk factors, and surgical management of CTR-IOL-CB complex subluxation/dislocation in a low-pseudoexfoliation area.Methods: Patients with CTR-IOL-CB complex subluxation/dislocation who had complete medical records at the Qingdao Eye Hospital of Shandong First Medical University between January 1994 and April 2024 were selected. Patient demographic data, incidence, interval, risk factors, extent of zonular weakness, IOL and CTR design and material, surgical management, visual acuity (VA), and other complications.Results: 31 cases aged 65.17 ± 7.19 years at CTR-IOL-CB complex subluxation/dislocation were reviewed; the interval was 41.23 ± 14.63 months after implantation of IOL and CTR. The incidence rate of CTR-IOL-CB complex subluxation/dislocation was 0.85%. The most common risk factors were ocular trauma and hypermature cataract. Extent of zonular weakness of ≥ 4 o’clock and the use of 1-piece hydrophilic acrylic and 3-piece hydrophobic acrylic IOLs were susceptible to complex subluxation/dislocation. VA was significantly increased after IOL repositioning or exchange; no other complications were present.Conclusion: Zonular insufficiency stabilized with IOL and CTR alone still carries a risk of re-dislocation. Ocular trauma and hypermature cataract were the most common risks in a low-pseudoexfoliation region. IOL exchange or repositioning is effective for this complication.Keywords: CTR-IOL-CB complex, subluxation/dislocation, incidence, zonule weakness, surgical management

SHILAP Revista de lepidopterología
Openalex Percentile: Top 43%
Music Technology and Sound Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Late Spontaneous in-the-Bag Capsular Tension Ring - Intraocular Lens - Capsular Bag Complex Subluxation in a Low-PEX Region: A Series of 31 Cases · SHILAP Revista de lepidopterología (2025) | TGRS Research Map | TGRS