Visual Performance and Refractive Stability of Clareon® Monofocal Intraocular Lens Implanted with an Automated Delivery System

Edward Tran,1,2 Nirmit Shah,2,3 Sandra Caballero Ortiz,2 Angela Kyveris,2 Graham Berg,2 Toby Chan2,4 1Schulich School of Medicine, University of Western Ontario, London, ON, Canada; 2Ocular Health Centre, Kitchener, ON, Canada; 3Melbourne Medical School, University of Melbourne, VIC, Australia; 4Michael G. DeGroote School of Medicine, McMaster University, Hamilton, ON, CanadaCorrespondence: Edward Tran, Ocular Health Centre, 31 Kingsbury Dr Unit #501, Kitchener, ON, N2A 0K5, Canada, Email [email protected]: To evaluate the visual performance, refractive stability, and glistening-free clarity of the Clareon® monofocal intraocular lens (IOL) implanted using the AutonoMe® automated delivery system in a real-world North American setting.Patients and Methods: A prospective, single-arm study was conducted at a single Canadian site involving 46 patients, or 85 eyes, undergoing cataract surgery with Clareon® IOL implantation. Eligible participants were ≥ 22 years old with best-corrected distance visual acuity (BCDVA) of 0.3 logMAR or worse, targeted for emmetropia, and had < 1.0 D of preoperative astigmatism. Exclusion criteria included retinal disease, glaucoma, amblyopia, corneal pathology, and prior intraocular or corneal surgery. Manifest refraction, uncorrected (UDVA), best-corrected (BCDVA), and low-contrast visual acuity (LCVA) were assessed at 1, 3, and 12 months postoperatively. Glistenings were graded using the Miyata scale at 3 and 12 months.Results: No statistically significant changes were observed in manifest refraction, UDVA, or BCDVA between 1 and 3 months (p > 0.05). At 3 months, the mean spherical equivalent was +0.09 D, with low residual astigmatism (– 0.33 D). Mean logMAR UDVA and BCDVA were 0.13 and 0.02, respectively. LCVA was 0.04 logMAR. No glistenings were observed at either 3 or 12 months in any patient. Refractive and visual outcomes remained stable over time, with no device-related complications reported.Conclusion: The Clareon® IOL demonstrated excellent refractive accuracy, stable visual performance, and sustained optical clarity with no glistenings up to one year postoperatively. Its compatibility with the AutonoMe® delivery system supports its utility as a reliable option for cataract surgery.Keywords: cataract surgery, Clareon, monofocal intraocular lens, automated delivery system, surgical outcomes

Institutions

Publication Details

Journal
SHILAP Revista de lepidopterología
Published
2025-10-01
Primary Topic
Ophthalmology and Visual Impairment Studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Visual Performance and Refractive Stability of Clareon® Monofocal Intraocular Lens Implanted with an Automated Delivery System

SHILAP Revista de lepidopterología
Ophthalmology and Visual Impairment Studies
article

Visual Performance and Refractive Stability of Clareon® Monofocal Intraocular Lens Implanted with an Automated Delivery System

article en

Abstract

Edward Tran,1,2 Nirmit Shah,2,3 Sandra Caballero Ortiz,2 Angela Kyveris,2 Graham Berg,2 Toby Chan2,4 1Schulich School of Medicine, University of Western Ontario, London, ON, Canada; 2Ocular Health Centre, Kitchener, ON, Canada; 3Melbourne Medical School, University of Melbourne, VIC, Australia; 4Michael G. DeGroote School of Medicine, McMaster University, Hamilton, ON, CanadaCorrespondence: Edward Tran, Ocular Health Centre, 31 Kingsbury Dr Unit #501, Kitchener, ON, N2A 0K5, Canada, Email [email protected]: To evaluate the visual performance, refractive stability, and glistening-free clarity of the Clareon® monofocal intraocular lens (IOL) implanted using the AutonoMe® automated delivery system in a real-world North American setting.Patients and Methods: A prospective, single-arm study was conducted at a single Canadian site involving 46 patients, or 85 eyes, undergoing cataract surgery with Clareon® IOL implantation. Eligible participants were ≥ 22 years old with best-corrected distance visual acuity (BCDVA) of 0.3 logMAR or worse, targeted for emmetropia, and had < 1.0 D of preoperative astigmatism. Exclusion criteria included retinal disease, glaucoma, amblyopia, corneal pathology, and prior intraocular or corneal surgery. Manifest refraction, uncorrected (UDVA), best-corrected (BCDVA), and low-contrast visual acuity (LCVA) were assessed at 1, 3, and 12 months postoperatively. Glistenings were graded using the Miyata scale at 3 and 12 months.Results: No statistically significant changes were observed in manifest refraction, UDVA, or BCDVA between 1 and 3 months (p > 0.05). At 3 months, the mean spherical equivalent was +0.09 D, with low residual astigmatism (– 0.33 D). Mean logMAR UDVA and BCDVA were 0.13 and 0.02, respectively. LCVA was 0.04 logMAR. No glistenings were observed at either 3 or 12 months in any patient. Refractive and visual outcomes remained stable over time, with no device-related complications reported.Conclusion: The Clareon® IOL demonstrated excellent refractive accuracy, stable visual performance, and sustained optical clarity with no glistenings up to one year postoperatively. Its compatibility with the AutonoMe® delivery system supports its utility as a reliable option for cataract surgery.Keywords: cataract surgery, Clareon, monofocal intraocular lens, automated delivery system, surgical outcomes

SHILAP Revista de lepidopterología
Ophthalmology Associates (United States) (US)
Reduced inequalities
Openalex Percentile: Top 36%
Ophthalmology and Visual Impairment Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.