QUANTITATIVE ANALYSIS OF SELECTED PHARMACEUTICALS VIA CERIUM (IV)-AMARANTH DYE COUPLED REACTION

Simple, sensitive, accurate, and precise spectrophotometric methods for quantitative determination of drugs, viz., Darifenacin (DAR), Esmolol Hydrochloride (ESM), Montelukast Sodium (MON), Sildenafil citrate (SIL),Terbinafine (TER) and Tramadol Hydrochloride (TRA) were developed. The method of each drug depends upon oxidation of drugs by Ce (IV) (Excess) and estimating the amount of unreacted Ce (IV) by amaranth dye at 523nm. The calibration curves obeyed Beer’s law over the concentration range of 1.4-7.0 µg ml-1 (DAR), 2-14 µg ml-1 (ESM), 2-10 µg ml-1 (MON), 20-70 µg ml-1 (SIL), 3-21 µg ml-1 (TER) & 2-14 µg ml-1 (TRA). The methods have been validated in terms of guidelines of ICH and applied to analysis of pharmaceuticals

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2025-10-24
DOI
https://doi.org/10.5281/zenodo.17432871
Primary Topic
Prenatal Screening and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

QUANTITATIVE ANALYSIS OF SELECTED PHARMACEUTICALS VIA CERIUM (IV)-AMARANTH DYE COUPLED REACTION

Zenodo (CERN European Organization for Nuclear Research)
Prenatal Screening and Diagnostics
article

QUANTITATIVE ANALYSIS OF SELECTED PHARMACEUTICALS VIA CERIUM (IV)-AMARANTH DYE COUPLED REACTION

article en

Abstract

Simple, sensitive, accurate, and precise spectrophotometric methods for quantitative determination of drugs, viz., Darifenacin (DAR), Esmolol Hydrochloride (ESM), Montelukast Sodium (MON), Sildenafil citrate (SIL),Terbinafine (TER) and Tramadol Hydrochloride (TRA) were developed. The method of each drug depends upon oxidation of drugs by Ce (IV) (Excess) and estimating the amount of unreacted Ce (IV) by amaranth dye at 523nm. The calibration curves obeyed Beer’s law over the concentration range of 1.4-7.0 µg ml-1 (DAR), 2-14 µg ml-1 (ESM), 2-10 µg ml-1 (MON), 20-70 µg ml-1 (SIL), 3-21 µg ml-1 (TER) & 2-14 µg ml-1 (TRA). The methods have been validated in terms of guidelines of ICH and applied to analysis of pharmaceuticals

Zenodo (CERN European Organization for Nuclear Research)
Osmania University (IN)
Openalex Percentile: Top 26%
Prenatal Screening and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.