Study and characterization of silicon photomultiplier
\nfor the outer time of flight layer of the future ALICE 3
\nexperiment

In this thesis, Silicon Photomultipliers (SiPMs) have been characterized for potential implementation in the future ALICE 3 experiment at the Large Hadron Collider (LHC), which will replace the current ALICE detector. ALICE 3 is an innovative experiment with a key focus on minimizing the material budget, as it will consist entirely of silicon, resulting in a highly lightweight structure. SiPM sensors are being studied for use in the outer Time Of Flight layer, where radiation levels are lower, and a time resolution of 20 ps is required. However, SiPMs are also excellent photon detectors, and their characterization involved both photon beam tests from a laser source and charged particle beam tests at CERN's Proton Synchrotron. 
\n
\nThe preliminary analysis includes an estimation of the Dark Count Rate (DCR) and measurements of current and capacitance as a function of voltage. Time resolution was assessed using both a laser photon source in the laboratory and charged particles at CERN's beam facilities at different beam energies. Additionally, an initial attempt to integrate the sensors into the full electronic readout chain, comprising the LiROC (Lidar ReadOut Chip) front-end ASIC and picoTDC, is presented.
\n
\nThe analyzed sensors differed in the thickness of the resin cover (3 mm, 1.5 mm, 1 mm, or no resin) and the presence of a thin metal layer in the trenches isolating the Single-Photon Avalanche Diodes (SPADs) (NUV-HD standard vs. NUV-HD-MT). While the metal layer was expected to improve isolation, no significant reduction in DCR was observed, and the time resolution appeared to worsen compared to standard sensors. The time resolution obtained with the laser source was approximately 120 ps, while values as low as 40 ps were achieved with charged particles beams.

Publication Details

Journal
AMS Degree Thesis (University of Bologna)
Published
2024-10-31
Primary Topic
Prenatal Screening and Diagnostics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Study and characterization of silicon photomultiplier
\nfor the outer time of flight layer of the future ALICE 3
\nexperiment

AMS Degree Thesis (University of Bologna)
Prenatal Screening and Diagnostics
article

Study and characterization of silicon photomultiplier
\nfor the outer time of flight layer of the future ALICE 3
\nexperiment

article en

Abstract

In this thesis, Silicon Photomultipliers (SiPMs) have been characterized for potential implementation in the future ALICE 3 experiment at the Large Hadron Collider (LHC), which will replace the current ALICE detector. ALICE 3 is an innovative experiment with a key focus on minimizing the material budget, as it will consist entirely of silicon, resulting in a highly lightweight structure. SiPM sensors are being studied for use in the outer Time Of Flight layer, where radiation levels are lower, and a time resolution of 20 ps is required. However, SiPMs are also excellent photon detectors, and their characterization involved both photon beam tests from a laser source and charged particle beam tests at CERN's Proton Synchrotron. 
\n
\nThe preliminary analysis includes an estimation of the Dark Count Rate (DCR) and measurements of current and capacitance as a function of voltage. Time resolution was assessed using both a laser photon source in the laboratory and charged particles at CERN's beam facilities at different beam energies. Additionally, an initial attempt to integrate the sensors into the full electronic readout chain, comprising the LiROC (Lidar ReadOut Chip) front-end ASIC and picoTDC, is presented.
\n
\nThe analyzed sensors differed in the thickness of the resin cover (3 mm, 1.5 mm, 1 mm, or no resin) and the presence of a thin metal layer in the trenches isolating the Single-Photon Avalanche Diodes (SPADs) (NUV-HD standard vs. NUV-HD-MT). While the metal layer was expected to improve isolation, no significant reduction in DCR was observed, and the time resolution appeared to worsen compared to standard sensors. The time resolution obtained with the laser source was approximately 120 ps, while values as low as 40 ps were achieved with charged particles beams.

AMS Degree Thesis (University of Bologna)
Industry, innovation and infrastructure
Openalex Percentile: Top 26%
Prenatal Screening and Diagnostics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.