Ventilation Opportunities in Air Conditioning Systems

This work applies Online Building Energy Simulation and Optimization programs (BESOO) to determine the energy conservation potential of ventilation when using air conditioning. The default ventilation is 10 changes per hour, equivalent to 1,560 CFM per 100m2 apartment. Ventilation saves more than 70% of energy for cooling at 25°C-26°C in Jerusalem and 25% in Tel Aviv. When cooling at 26°C, ventilation reduces the Heat Index discomfort period by 99% (from 911 to 11 hours per year) in Jerusalem and 55% in Tel Aviv. The default ventilation in this work was 10 changes per hour; however, after 4 changes per hour (600 CFM for a 100m2 apartment), the impact of increased ventilation volume is very low. When operating at the optimum comfort (OCAC) cooling temperature, the ventilation saves 74% of cooling hours in Jerusalem and 40% in Tel Aviv.

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2025-10-23
DOI
https://doi.org/10.5281/zenodo.17423419
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ventilation Opportunities in Air Conditioning Systems

Zenodo (CERN European Organization for Nuclear Research)
Building Energy and Comfort Optimization
article

Ventilation Opportunities in Air Conditioning Systems

article en

Abstract

This work applies Online Building Energy Simulation and Optimization programs (BESOO) to determine the energy conservation potential of ventilation when using air conditioning. The default ventilation is 10 changes per hour, equivalent to 1,560 CFM per 100m2 apartment. Ventilation saves more than 70% of energy for cooling at 25°C-26°C in Jerusalem and 25% in Tel Aviv. When cooling at 26°C, ventilation reduces the Heat Index discomfort period by 99% (from 911 to 11 hours per year) in Jerusalem and 55% in Tel Aviv. The default ventilation in this work was 10 changes per hour; however, after 4 changes per hour (600 CFM for a 100m2 apartment), the impact of increased ventilation volume is very low. When operating at the optimum comfort (OCAC) cooling temperature, the ventilation saves 74% of cooling hours in Jerusalem and 40% in Tel Aviv.

Zenodo (CERN European Organization for Nuclear Research)
Affordable and clean energy
Openalex Percentile: Top 47%
Building Energy and Comfort Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.