FIRST INSIGHTS INTO RADON EMISSION USING BARE MODE IN RAMPUR DISTRICT OF INDIA

Measurement of radon, thoron concentration and their daughter products in a dwelling of Rampur city and in the surrounding villages were carried out by using Solid-state nuclear track detectors (LR-115 type II) in a bare mode. The detectors were distributed over 32 houses. The indoor radon concentration was found to vary with building material, ventilation condition, occupant’s behavior and mode of constructions of houses. The radon value was found to be lower than recommended value under normal ventilation condition. The indoor radon concentrations were found to vary from 30 Bqm-3 to 85.36Bqm-3 with an average value of 62.36 Bq/m3.This value is lower than the ICRP recommended values of 200Bqm-and thus are within safe limits. The outdoor radon concentration is usually low and less than average indoor levels. It is also found that, in general, the radon level in lower floors is higher than that in upper ones in all houses

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2025-10-22
DOI
https://doi.org/10.5281/zenodo.17414925
Primary Topic
Radioactivity and Radon Measurements
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

FIRST INSIGHTS INTO RADON EMISSION USING BARE MODE IN RAMPUR DISTRICT OF INDIA

Zenodo (CERN European Organization for Nuclear Research)
Radioactivity and Radon Measurements
article

FIRST INSIGHTS INTO RADON EMISSION USING BARE MODE IN RAMPUR DISTRICT OF INDIA

article en

Abstract

Measurement of radon, thoron concentration and their daughter products in a dwelling of Rampur city and in the surrounding villages were carried out by using Solid-state nuclear track detectors (LR-115 type II) in a bare mode. The detectors were distributed over 32 houses. The indoor radon concentration was found to vary with building material, ventilation condition, occupant’s behavior and mode of constructions of houses. The radon value was found to be lower than recommended value under normal ventilation condition. The indoor radon concentrations were found to vary from 30 Bqm-3 to 85.36Bqm-3 with an average value of 62.36 Bq/m3.This value is lower than the ICRP recommended values of 200Bqm-and thus are within safe limits. The outdoor radon concentration is usually low and less than average indoor levels. It is also found that, in general, the radon level in lower floors is higher than that in upper ones in all houses

Zenodo (CERN European Organization for Nuclear Research)
Uttar Pradesh Council of sugarcane research (IN)
Sustainable cities and communities
Openalex Percentile: Top 38%
Radioactivity and Radon Measurements
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.