Research on ventilation of nuclear facilities based on Modelica

Taking the ventilation system of a comprehensive experimental platform in the experimental base as the research, a multi-zone ventilation model was established based on Modelica, and ventilation simulation and experimental research were conducted under multiple working conditions. The results indicate that the multi-zone model established using Modelica can provide reliable tools and methods for the design and research of ventilation containment in nuclear facility buildings. Under the maintenance conditions of nuclear facilities, there may be a sudden jump in pressure differential, which poses a potential risk of pollutant diffusion, and the pressure differential in other equipment rooms under the same exhaust system will decrease accordingly; Under heating conditions, the pressure differential in the heated room gradually increases, while the pressure differential in other equipment rooms is not significantly affected.

Institutions

Publication Details

Journal
International Journal of Advanced Nuclear Reactor Design and Technology
Published
2025-10-23
DOI
https://doi.org/10.1016/j.jandt.2025.10.006
Primary Topic
Nuclear Engineering Thermal-Hydraulics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on ventilation of nuclear facilities based on Modelica

International Journal of Advanced Nuclear Reactor Design and Technology
Nuclear Engineering Thermal-Hydraulics
article

Research on ventilation of nuclear facilities based on Modelica

article en

Abstract

Taking the ventilation system of a comprehensive experimental platform in the experimental base as the research, a multi-zone ventilation model was established based on Modelica, and ventilation simulation and experimental research were conducted under multiple working conditions. The results indicate that the multi-zone model established using Modelica can provide reliable tools and methods for the design and research of ventilation containment in nuclear facility buildings. Under the maintenance conditions of nuclear facilities, there may be a sudden jump in pressure differential, which poses a potential risk of pollutant diffusion, and the pressure differential in other equipment rooms under the same exhaust system will decrease accordingly; Under heating conditions, the pressure differential in the heated room gradually increases, while the pressure differential in other equipment rooms is not significantly affected.

International Journal of Advanced Nuclear Reactor Design and TechnologyVol. 7(4)
Tianjin University (CN), China General Nuclear Power Corporation (China) (CN)
Openalex Percentile: Top 34%
Nuclear Engineering Thermal-Hydraulics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Research on ventilation of nuclear facilities based on Modelica · International Journal of Advanced Nuclear Reactor Design and Technology (2025) | TGRS Research Map | TGRS