A Variable Length Biopsy Device Designed for Improved Prostate Cancer Detection vs the Standard Biopsy Device: Pathological Comparisons and Needle Length Requirements for Men Undergoing Transperineal Biopsy

Purpose: To investigate a novel prostate biopsy device capable of taking specimens between 1.5 and 5.5 cm in length and to determine the distances from apex to base in men undergoing transperineal biopsy. Materials and Methods: An actuator was developed capable of firing an 18-gauge true-cut biopsy needle with a specimen notch of 5.5 cm adjustable at 1 mm between 1.5 and 5.5 cm. The length of specimens retrieved vs the notch length was determined using fresh porcine kidneys and compared with a Bard device. The distance from prostate apex to base was determined in men undergoing transperineal biopsy using a proprietary software program. The program determined apex to base lengths throughout the gland. The number of needles required to span the prostate between ≤ 2.0 cm to > 5.0 cm was also determined. Results: The variable length device outperformed the Bard device at different lengths collecting an average of 88% vs 82% of the notch length (n = 576, P < .001). The mean biopsy needle length required for an average prostate volume of 48.2 cc was 3.4 cm. 79.6% of the biopsies taken with the Bard device would not have reached that distance. The new needle collected 5.8 mm 3 of tissue vs 3.8 mm 3 (1.5 times more) for the Bard device. Conclusions: The variable length biopsy device can sample the prostate to 5.5 cm in length with an average of 88% of the specimen collected. Eighty percent of men would need a biopsy needle longer than what is typically used in clinical practice.

Institutions

Publication Details

Journal
JU Open Plus
Published
2025-10-01
DOI
https://doi.org/10.1097/ju9.0000000000000376
Primary Topic
Prostate Cancer Diagnosis and Treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Variable Length Biopsy Device Designed for Improved Prostate Cancer Detection vs the Standard Biopsy Device: Pathological Comparisons and Needle Length Requirements for Men Undergoing Transperineal Biopsy

JU Open Plus
Prostate Cancer Diagnosis and Treatment
article

A Variable Length Biopsy Device Designed for Improved Prostate Cancer Detection vs the Standard Biopsy Device: Pathological Comparisons and Needle Length Requirements for Men Undergoing Transperineal Biopsy

article en

Abstract

Purpose: To investigate a novel prostate biopsy device capable of taking specimens between 1.5 and 5.5 cm in length and to determine the distances from apex to base in men undergoing transperineal biopsy. Materials and Methods: An actuator was developed capable of firing an 18-gauge true-cut biopsy needle with a specimen notch of 5.5 cm adjustable at 1 mm between 1.5 and 5.5 cm. The length of specimens retrieved vs the notch length was determined using fresh porcine kidneys and compared with a Bard device. The distance from prostate apex to base was determined in men undergoing transperineal biopsy using a proprietary software program. The program determined apex to base lengths throughout the gland. The number of needles required to span the prostate between ≤ 2.0 cm to > 5.0 cm was also determined. Results: The variable length device outperformed the Bard device at different lengths collecting an average of 88% vs 82% of the notch length (n = 576, P < .001). The mean biopsy needle length required for an average prostate volume of 48.2 cc was 3.4 cm. 79.6% of the biopsies taken with the Bard device would not have reached that distance. The new needle collected 5.8 mm 3 of tissue vs 3.8 mm 3 (1.5 times more) for the Bard device. Conclusions: The variable length biopsy device can sample the prostate to 5.5 cm in length with an average of 88% of the specimen collected. Eighty percent of men would need a biopsy needle longer than what is typically used in clinical practice.

JU Open PlusVol. 3(10)
University of California, San Francisco (US), Ansys (United States) (US), University of California San Diego (US), Hygeia Hospital (GR), University of Amsterdam (NL), University of Colorado Colorado Springs (US), Icahn School of Medicine at Mount Sinai (US)
Good health and well-being
Openalex Percentile: Top 33%
Prostate Cancer Diagnosis and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A Variable Length Biopsy Device Designed for Improved Prostate Cancer Detection vs the Standard Biopsy Device: Pathological Comparisons and Needle Length Requirements for Men Undergoing Transperineal Biopsy · JU Open Plus (2025) | TGRS Research Map | TGRS