Peri-Implant Supracrestal Tissue Characteristics Related to Abutment Materials: A Comparative Histomorphometry Study.

Background The peri-implant soft tissue integration is critical to maintain peri-implant health and the long-term success of dental implant rehabilitations. Aim This comparative histomorphometry study aims to characterize the peri-implant soft tissues (PIST) around experimental abutments made of titanium (Ti), dental resin (Re), and polyetheretherketone (PEEK). Methods Thirty bone-level implants were placed, each receiving an experimental transmucosal healing abutment made of one of the three materials. After an 8-week healing period, the abutments and surrounding tissues were harvested and prepared for histological and histomorphometric analyses. Dimensions of sulcus depth, epithelial and connective tissue adhesion were measured. In addition, the abutment surface characteristics, levels of inflammation, plaque accumulation, and peri-implant bone level changes were evaluated. Results The dimensions of the different components of the PIST were comparable across the three experimental groups. The mean overall dimensions of the PIST were 2.68 ± 0.51 mm for Ti, 2.66 ± 0.47 mm for Re, and 2.32 ± 0.55 mm for PEEK. Mean sulcus depth was 0.71 ± 0.69 mm for Ti, 0.74 ± 0.50 mm for Re, and 0.68 ± 0.63 mm for PEEK. Mean junctional epithelium was 1.82 ± 0.67 mm for Ti, 1.56 ± 0.47 mm for Re, and 1.53 ± 0.40 mm for PEEK. Mean harvested connective tissue (until abutment platform) was 0.30 ± 0.29 mm for Ti, 0.36 ± 0.38 mm for Re, and 0.09 ± 0.10 mm for PEEK. However, the resin group exhibited significantly more supramucosal biofilm adhesion (p = 0.026). Conclusion The PIST around abutments made of PEEK, resin, or titanium tend to develop in a similar pattern. However, longer observation periods are required to evaluate the long-term effects.

Institutions

Publication Details

Journal
Open Access CRIS of the University of Bern
Published
2025-10-01
DOI
https://doi.org/10.48620/91757
Primary Topic
Fetal and Pediatric Neurological Disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Peri-Implant Supracrestal Tissue Characteristics Related to Abutment Materials: A Comparative Histomorphometry Study.

Open Access CRIS of the University of Bern
Fetal and Pediatric Neurological Disorders
article

Peri-Implant Supracrestal Tissue Characteristics Related to Abutment Materials: A Comparative Histomorphometry Study.

article en

Abstract

Background The peri-implant soft tissue integration is critical to maintain peri-implant health and the long-term success of dental implant rehabilitations. Aim This comparative histomorphometry study aims to characterize the peri-implant soft tissues (PIST) around experimental abutments made of titanium (Ti), dental resin (Re), and polyetheretherketone (PEEK). Methods Thirty bone-level implants were placed, each receiving an experimental transmucosal healing abutment made of one of the three materials. After an 8-week healing period, the abutments and surrounding tissues were harvested and prepared for histological and histomorphometric analyses. Dimensions of sulcus depth, epithelial and connective tissue adhesion were measured. In addition, the abutment surface characteristics, levels of inflammation, plaque accumulation, and peri-implant bone level changes were evaluated. Results The dimensions of the different components of the PIST were comparable across the three experimental groups. The mean overall dimensions of the PIST were 2.68 ± 0.51 mm for Ti, 2.66 ± 0.47 mm for Re, and 2.32 ± 0.55 mm for PEEK. Mean sulcus depth was 0.71 ± 0.69 mm for Ti, 0.74 ± 0.50 mm for Re, and 0.68 ± 0.63 mm for PEEK. Mean junctional epithelium was 1.82 ± 0.67 mm for Ti, 1.56 ± 0.47 mm for Re, and 1.53 ± 0.40 mm for PEEK. Mean harvested connective tissue (until abutment platform) was 0.30 ± 0.29 mm for Ti, 0.36 ± 0.38 mm for Re, and 0.09 ± 0.10 mm for PEEK. However, the resin group exhibited significantly more supramucosal biofilm adhesion (p = 0.026). Conclusion The PIST around abutments made of PEEK, resin, or titanium tend to develop in a similar pattern. However, longer observation periods are required to evaluate the long-term effects.

Open Access CRIS of the University of Bern
University of Dental Medicine (MM)
Openalex Percentile: Top 27%
Fetal and Pediatric Neurological Disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Peri-Implant Supracrestal Tissue Characteristics Related to Abutment Materials: A Comparative Histomorphometry Study. · Open Access CRIS of the University of Bern (2025) | TGRS Research Map | TGRS