Use of the tracheal bisecting line to differentiate upper pole from lower pole parathyroid adenomas: a PET/MR study using [18F]Fluorocholine.

Purpose Accurate preoperative localization of parathyroid adenomas is crucial in managing primary hyperparathyroidism (pHPT). Although [18F]Fluorocholine PET/CT and PET/MR have shown superior sensitivity over conventional imaging, distinguishing upper from lower pole adenomas remains challenging due to the invisibility of the recurrent laryngeal nerve. This study introduces the "tracheal bisecting line" (TBL), a novel anatomical landmark on axial PET/MR images, to aid in polarity differentiation. Methods This retrospective study included 110 patients (128 adenomas) with biochemically confirmed pHPT who underwent [18F]Fluorocholine PET/MR at the University Hospital Zurich between December 2020 and October 2023. Adenomas were classified as upper (posterior to the TBL), lower (anterior), with mid-TBL cases (neither anterior nor posterior) treated as upper per default, according to evidence from surgical experience. Two board-certified readers independently assessed the images. Surgical findings served as the reference. Inter-reader agreement was evaluated using weighted kappa statistics, and diagnostic accuracy was calculated for all adenomas and subgroups: orthotopic, non-orthotopic, and intrathyroidal. Results Among the 128 adenomas, 109 were orthotopic and 19 non-orthotopic (6 intrathyroidal). The inter-reader agreement was nearly perfect (κ = 0.99). The overall accuracy using the TBL was 0.945. The accuracy improved to 0.982 for orthotopic adenomas but decreased to 0.789 for non-orthotopic and 0.667 for intrathyroidal cases. Excluding intrathyroidal adenomas raised accuracy to 1.0 in non-orthotopic cases and 0.959 overall for non-intrathyroidal adenomas. Conclusions The TBL is a reliable and reproducible landmark on [18F]Fluorocholine PET/MR for predicting parathyroid adenoma polarity, particularly in orthotopic and non-intrathyroidal cases. It may enhance surgical planning by improving anatomical clarity.

Institutions

Publication Details

Journal
Open Access CRIS of the University of Bern
Published
2025-10-20
DOI
https://doi.org/10.48620/91800
Primary Topic
Data Visualization and Analytics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Use of the tracheal bisecting line to differentiate upper pole from lower pole parathyroid adenomas: a PET/MR study using [18F]Fluorocholine.

Open Access CRIS of the University of Bern
Data Visualization and Analytics
article

Use of the tracheal bisecting line to differentiate upper pole from lower pole parathyroid adenomas: a PET/MR study using [18F]Fluorocholine.

article en

Abstract

Purpose Accurate preoperative localization of parathyroid adenomas is crucial in managing primary hyperparathyroidism (pHPT). Although [18F]Fluorocholine PET/CT and PET/MR have shown superior sensitivity over conventional imaging, distinguishing upper from lower pole adenomas remains challenging due to the invisibility of the recurrent laryngeal nerve. This study introduces the "tracheal bisecting line" (TBL), a novel anatomical landmark on axial PET/MR images, to aid in polarity differentiation. Methods This retrospective study included 110 patients (128 adenomas) with biochemically confirmed pHPT who underwent [18F]Fluorocholine PET/MR at the University Hospital Zurich between December 2020 and October 2023. Adenomas were classified as upper (posterior to the TBL), lower (anterior), with mid-TBL cases (neither anterior nor posterior) treated as upper per default, according to evidence from surgical experience. Two board-certified readers independently assessed the images. Surgical findings served as the reference. Inter-reader agreement was evaluated using weighted kappa statistics, and diagnostic accuracy was calculated for all adenomas and subgroups: orthotopic, non-orthotopic, and intrathyroidal. Results Among the 128 adenomas, 109 were orthotopic and 19 non-orthotopic (6 intrathyroidal). The inter-reader agreement was nearly perfect (κ = 0.99). The overall accuracy using the TBL was 0.945. The accuracy improved to 0.982 for orthotopic adenomas but decreased to 0.789 for non-orthotopic and 0.667 for intrathyroidal cases. Excluding intrathyroidal adenomas raised accuracy to 1.0 in non-orthotopic cases and 0.959 overall for non-intrathyroidal adenomas. Conclusions The TBL is a reliable and reproducible landmark on [18F]Fluorocholine PET/MR for predicting parathyroid adenoma polarity, particularly in orthotopic and non-intrathyroidal cases. It may enhance surgical planning by improving anatomical clarity.

Open Access CRIS of the University of Bern
Society of Interventional Radiology (US)
Openalex Percentile: Top 43%
Data Visualization and Analytics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Use of the tracheal bisecting line to differentiate upper pole from lower pole parathyroid adenomas: a PET/MR study using [18F]Fluorocholine. · Open Access CRIS of the University of Bern (2025) | TGRS Research Map | TGRS