PASSIVE SEISMIC PROTECTION IN RC STRUCTURES WITH SOFT GROUND FLOOR

The increasingly common design of reinforced concrete (RC) structures with soft stories in seismically active areas requires a more detailed calculation approach and the introduction of special seismic solutions. A soft story refers to an open ground floor space, while the upper floors are masonry. Regarding earthquake effects, the most unfavorable and at the same time the most common variant is the construction of "soft stories" on the ground floor of buildings. The paper presents the principle of nonlinear static analysis, based on the application of the N2 method as a representative nonlinear static method supported by Eurocode 8. A nonlinear static analysis model of two RC structures with a soft story is shown, where the impact of masonry infill is considered. In one model, metal-yielding dampers, specifically the DC90 SYSTEM, are used on the ground floor as a special type of passive seismic protection. The results of the nonlinear static analysis are then presented in the form of a pushover curve, displacement diagrams, relative story displacements, and the distribution scheme of plastic hinges, all with the aim of evaluating the efficiency of metal-yielding dampers. The general conclusion that emerges from the presented results of the numerical investigation is that the DC90 SYSTEM has a significant impact on improving the seismic performance of RC frame structures with a soft story. By applying this passive seismic protection system, inter-story drifts on the ground floor are reduced, the overall displacement of the building is decreased, and the soft story mechanism transforms into a more favorable beam failure mechanism. Considering the market price of this type of damper, it can be concluded that the initial investment in seismic protection is significantly lower than the cost of repairing a damaged building after a moderate earthquake, while the contribution to preventing the collapse of the structure during strong earthquakes and preserving human lives is invaluable.

Institutions

Publication Details

Journal
Zenodo (CERN European Organization for Nuclear Research)
Published
2025-10-18
DOI
https://doi.org/10.5281/zenodo.17383475
Primary Topic
Data Analysis with R
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

PASSIVE SEISMIC PROTECTION IN RC STRUCTURES WITH SOFT GROUND FLOOR

Zenodo (CERN European Organization for Nuclear Research)
Data Analysis with R
article

PASSIVE SEISMIC PROTECTION IN RC STRUCTURES WITH SOFT GROUND FLOOR

article en

Abstract

The increasingly common design of reinforced concrete (RC) structures with soft stories in seismically active areas requires a more detailed calculation approach and the introduction of special seismic solutions. A soft story refers to an open ground floor space, while the upper floors are masonry. Regarding earthquake effects, the most unfavorable and at the same time the most common variant is the construction of "soft stories" on the ground floor of buildings. The paper presents the principle of nonlinear static analysis, based on the application of the N2 method as a representative nonlinear static method supported by Eurocode 8. A nonlinear static analysis model of two RC structures with a soft story is shown, where the impact of masonry infill is considered. In one model, metal-yielding dampers, specifically the DC90 SYSTEM, are used on the ground floor as a special type of passive seismic protection. The results of the nonlinear static analysis are then presented in the form of a pushover curve, displacement diagrams, relative story displacements, and the distribution scheme of plastic hinges, all with the aim of evaluating the efficiency of metal-yielding dampers. The general conclusion that emerges from the presented results of the numerical investigation is that the DC90 SYSTEM has a significant impact on improving the seismic performance of RC frame structures with a soft story. By applying this passive seismic protection system, inter-story drifts on the ground floor are reduced, the overall displacement of the building is decreased, and the soft story mechanism transforms into a more favorable beam failure mechanism. Considering the market price of this type of damper, it can be concluded that the initial investment in seismic protection is significantly lower than the cost of repairing a damaged building after a moderate earthquake, while the contribution to preventing the collapse of the structure during strong earthquakes and preserving human lives is invaluable.

Zenodo (CERN European Organization for Nuclear Research)
State University of Novi Pazar (RS)
Sustainable cities and communities
Openalex Percentile: Top 23%
Data Analysis with R
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

PASSIVE SEISMIC PROTECTION IN RC STRUCTURES WITH SOFT GROUND FLOOR · Zenodo (CERN European Organization for Nuclear Research) (2025) | TGRS Research Map | TGRS