Influence of polypropylene content in PPLP for high voltage insulation at cryogenic temperature
This study compares the dielectric performance of polypropylene-laminated paper (PPLP) insulation impregnated with liquid nitrogen in the context of high-power superconducting cables within the SCARLET European project. Samples with polypropylene (PP) contents of 43 % and 55 % are tested in a representative cable geometry including almost 20 % gap density in the insulation. Breakdown voltage is found to increase with hydrostatic pressure. Weibull analysis predicts similar breakdown field strength at 63 % probability for both kinds of samples (about 89 kV/mm) but a larger scale parameter for 55 %-PP-content sample (about 10 versus 7). This better performance for 55 % PP content is mitigated by a larger brittleness upon breakdown.
Institutions
- Sorbonne Université (FR)
- Nexans (France) (FR)
- Columbus Superconductors (Italy) (IT)
- Laboratoire Médiations (FR)
Publication Details
- Journal
- Zenodo (CERN European Organization for Nuclear Research)
- Published
- 2025-10-01
- DOI
- https://doi.org/10.5281/zenodo.17356052
- Primary Topic
- High voltage insulation and dielectric phenomena
- Type
- article
- Field-Weighted Citation Impact