Lightweight Baselines for Medical Abstract Classification: DistilBERT with Cross-Entropy as a Strong Default

The research evaluates lightweight medical abstract classification methods to establish their maximum performance capabilities under financial budget restrictions. On the public medical abstracts corpus, we finetune BERT base and Distil BERT with three objectives cross entropy (CE), class weighted CE, and focal loss under identical tokenization, sequence length, optimizer, and schedule. DistilBERT with plain CE gives the strongest raw argmax trade off, while a post hoc operating point selection (validation calibrated, classwise thresholds) sub stantially improves deployed performance; under this tuned regime, focal benefits most. We report Accuracy, Macro F1, and WeightedF1, release evaluation artifacts, and include confusion analyses to clarify error structure. The practical takeaway is to start with a compact encoder and CE, then add lightweight calibration or thresholding when deployment requires higher macro balance.

Publication Details

Journal
ArXiv.org
Published
2025-10-11
Primary Topic
Imbalanced Data Classification Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Lightweight Baselines for Medical Abstract Classification: DistilBERT with Cross-Entropy as a Strong Default

ArXiv.org
Imbalanced Data Classification Techniques
article

Lightweight Baselines for Medical Abstract Classification: DistilBERT with Cross-Entropy as a Strong Default

article en

Abstract

The research evaluates lightweight medical abstract classification methods to establish their maximum performance capabilities under financial budget restrictions. On the public medical abstracts corpus, we finetune BERT base and Distil BERT with three objectives cross entropy (CE), class weighted CE, and focal loss under identical tokenization, sequence length, optimizer, and schedule. DistilBERT with plain CE gives the strongest raw argmax trade off, while a post hoc operating point selection (validation calibrated, classwise thresholds) sub stantially improves deployed performance; under this tuned regime, focal benefits most. We report Accuracy, Macro F1, and WeightedF1, release evaluation artifacts, and include confusion analyses to clarify error structure. The practical takeaway is to start with a compact encoder and CE, then add lightweight calibration or thresholding when deployment requires higher macro balance.

ArXiv.org
Partnerships for the goals
Openalex Percentile: Top 24%
Imbalanced Data Classification Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.