In-situ Radiation Damage Study of Silicon Carbide Detectors Subjected to Clinical Proton Beams

Silicon carbide (SiC) planar PiN diodes from two different manufacturers were irradiated with 252.7 MeV protons from a medical synchrotron. Over the course of two 8h irradiation shifts, the samples were exposed to increasing fluences ranging from 1.4e+11 to 3.5e+13 p+/cm^2. Electrical characterizations, including IV and CV measurements, were performed both before and after irradiation using probe stations, and for selected samples even in-situ between fluence steps directly at the irradiation facility. The results show a gradual compensation of the effective epitaxial doping concentration with each incremental fluence step, observed as a reduction in capacitance before full depletion and confirmed by the extracted effective doping concentration. From these measurements, linear donor removal rates are determined for all sample groups, with values ranging from 4.2/cm to 6.4/cm. These findings provide a quantitative basis for understanding radiation-induced charge carrier removal in 4H-SiC devices and are relevant for predicting the performance and lifetime of future radiation-hard detector technologies, including 4H-SiC LGADs.

Publication Details

Journal
ArXiv.org
Published
2025-10-13
Primary Topic
Colonialism, slavery, and trade
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

In-situ Radiation Damage Study of Silicon Carbide Detectors Subjected to Clinical Proton Beams

ArXiv.org
Colonialism, slavery, and trade
article

In-situ Radiation Damage Study of Silicon Carbide Detectors Subjected to Clinical Proton Beams

article en

Abstract

Silicon carbide (SiC) planar PiN diodes from two different manufacturers were irradiated with 252.7 MeV protons from a medical synchrotron. Over the course of two 8h irradiation shifts, the samples were exposed to increasing fluences ranging from 1.4e+11 to 3.5e+13 p+/cm^2. Electrical characterizations, including IV and CV measurements, were performed both before and after irradiation using probe stations, and for selected samples even in-situ between fluence steps directly at the irradiation facility. The results show a gradual compensation of the effective epitaxial doping concentration with each incremental fluence step, observed as a reduction in capacitance before full depletion and confirmed by the extracted effective doping concentration. From these measurements, linear donor removal rates are determined for all sample groups, with values ranging from 4.2/cm to 6.4/cm. These findings provide a quantitative basis for understanding radiation-induced charge carrier removal in 4H-SiC devices and are relevant for predicting the performance and lifetime of future radiation-hard detector technologies, including 4H-SiC LGADs.

ArXiv.org
Openalex Percentile: Top 36%
Colonialism, slavery, and trade
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

In-situ Radiation Damage Study of Silicon Carbide Detectors Subjected to Clinical Proton Beams · ArXiv.org (2025) | TGRS Research Map | TGRS