Development of the first 1 GHz niobium-tin quarter-wave cavity

Niobium-Tin (Nb3Sn) is a promising alternative to pure niobium for low-beta ion accelerators due to low RF losses even at high frequencies. At 4.5 K, the expected Bardeen-Cooper-Schrieffer resistance of Nb3Sn is a few nano-Ohms at 1 GHz, with two orders of magnitude improvement compared to pure niobium. The low Nb3Sn RF losses allow the use of higher frequency, much smaller cavities while maintaining 4.5 K operation that is compatible with cryocoolers. This work aims to demonstrate the feasibility of coating a high-frequency 1 GHz, compact quarter-wave cavity. The development of this cavity has the potential to transform low-beta ion accelerators through size reductions and by enabling the replacement of large helium cryoplants with small plug-in cryocoolers. We have designed, built, and tested a 1GHz Nb3Sn coated quarter-wave cavity. Nb3Sn coating has been performed once by vapor diffusion at Fermilab. Cryogenic cold tests show a quality factor of ~1E9 at low accelerating electric fields or ~7 times higher than the theoretical limit for pure niobium at 1GHz. This first coating does not yet meet our quality factor or gradient goals; however, we plan to continue to develop this cavity.

Publication Details

Journal
JACOW
Published
2025-10-14
DOI
https://doi.org/10.18429/jacow-hiat2025-tuc04
Primary Topic
Decolonial Thought and Epistemologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development of the first 1 GHz niobium-tin quarter-wave cavity

JACOW
Decolonial Thought and Epistemologies
article

Development of the first 1 GHz niobium-tin quarter-wave cavity

article en

Abstract

Niobium-Tin (Nb3Sn) is a promising alternative to pure niobium for low-beta ion accelerators due to low RF losses even at high frequencies. At 4.5 K, the expected Bardeen-Cooper-Schrieffer resistance of Nb3Sn is a few nano-Ohms at 1 GHz, with two orders of magnitude improvement compared to pure niobium. The low Nb3Sn RF losses allow the use of higher frequency, much smaller cavities while maintaining 4.5 K operation that is compatible with cryocoolers. This work aims to demonstrate the feasibility of coating a high-frequency 1 GHz, compact quarter-wave cavity. The development of this cavity has the potential to transform low-beta ion accelerators through size reductions and by enabling the replacement of large helium cryoplants with small plug-in cryocoolers. We have designed, built, and tested a 1GHz Nb3Sn coated quarter-wave cavity. Nb3Sn coating has been performed once by vapor diffusion at Fermilab. Cryogenic cold tests show a quality factor of ~1E9 at low accelerating electric fields or ~7 times higher than the theoretical limit for pure niobium at 1GHz. This first coating does not yet meet our quality factor or gradient goals; however, we plan to continue to develop this cavity.

JACOW
Affordable and clean energy
Openalex Percentile: Top 36%
Decolonial Thought and Epistemologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.