Particle identification using trajectory reconstruction with the ARIS separator system at FRIB

The production of radioactive beams is crucial to understand structure of atomic nuclei away from stability. The operation of FRIB will ultimately provide access to previously unreachable unstable nuclei. Radioactive beams produced at FRIB can be selected and purified using the Advanced Rare Isotope Separator (ARIS) for further study by users. Ions are identified based on the energy loss, magnetic rigidity, gamma rays, time of flight, total energy in a suite of detectors. The transport of cocktail beams to the end of ARIS can impact the path length and the measured flight time. This can lead to uncertainty in the particle identification and worse timing resolution can occur if not corrected for. Characterizing the ion optics with position-sensitive detectors allows for corrections to the flight path of the ions. This in conjunction with the use of transfer matrices allows for the particle’s trajectory to be reconstructed and thus correct for the variation in the measured time of flight. These corrections are crucial for enhancing charge-state identification, especially in a high-resolution optics mode. The impact of applying a trajectory reconstruction method will be presented.

Publication Details

Journal
JACOW
Published
2025-10-14
DOI
https://doi.org/10.18429/jacow-hiat2025-fra03
Primary Topic
Nuclear physics research studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Particle identification using trajectory reconstruction with the ARIS separator system at FRIB

JACOW
Nuclear physics research studies
article

Particle identification using trajectory reconstruction with the ARIS separator system at FRIB

article en

Abstract

The production of radioactive beams is crucial to understand structure of atomic nuclei away from stability. The operation of FRIB will ultimately provide access to previously unreachable unstable nuclei. Radioactive beams produced at FRIB can be selected and purified using the Advanced Rare Isotope Separator (ARIS) for further study by users. Ions are identified based on the energy loss, magnetic rigidity, gamma rays, time of flight, total energy in a suite of detectors. The transport of cocktail beams to the end of ARIS can impact the path length and the measured flight time. This can lead to uncertainty in the particle identification and worse timing resolution can occur if not corrected for. Characterizing the ion optics with position-sensitive detectors allows for corrections to the flight path of the ions. This in conjunction with the use of transfer matrices allows for the particle’s trajectory to be reconstructed and thus correct for the variation in the measured time of flight. These corrections are crucial for enhancing charge-state identification, especially in a high-resolution optics mode. The impact of applying a trajectory reconstruction method will be presented.

JACOW
Affordable and clean energy
Openalex Percentile: Top 30%
Nuclear physics research studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Particle identification using trajectory reconstruction with the ARIS separator system at FRIB · JACOW (2025) | TGRS Research Map | TGRS